Skip to main content
. 2007 Apr 19;8(2):47–60. doi: 10.1120/jacmp.v8i2.2423

Table 2.

Planning tumor cone down volume (PTVcd) mean and equivalent uniform doses (EUDs) delivered by intensity‐modulated radiation therapy (IMRT) and three‐dimensional conformal radiation therapy (3D‐CRT) plans

Dose (Gy)
Mean EUD
Case IMRT 3D‐CRT IMRT 3D‐CRT
1 62.52 59.83 60.95 59.38
2 62.07 60.71 60.39 57.89
3 61.45 59.53 61.13 59.35
4 61.98 59.91 61.65 58.96
5 61.47 60.20 59.82 50.02
6 60.88 60.68 60.78 60.53
7 61.75 60.47 60.47 57.58
8 62.52 60.27 62.27 59.91
9 60.05 59.20 56.32 50.21
10 61.68 58.62 60.74 54.76
11 61.42 59.01 59.66 56.42
12 61.85 59.59 58.94 58.00
13 61.80 59.96 61.42 59.88
14 61.10 60.90 60.91 60.63
15 62.21 60.94 61.89 60.02
16 61.75 60.41 61.02 59.95
17 62.08 60.49 61.98 60.18
18 61.65 60.39 61.44 60.18
19 62.96 60.96 62.26 59.96
20 61.70 59.19 61.10 57.33
Average 61.74 60.06 60.76 58.06