Skip to main content
. 2007 Apr 19;8(2):47–60. doi: 10.1120/jacmp.v8i2.2423

Table 3.

Percent normal brain volumes receiving doses equal to or higher than 18, 24, and 45 Gy with intensity‐modulated radiation therapy (IMRT) and three‐dimensional conformal radiation therapy (3D‐CRT) plans

Volume (%)
18 Gy 24 Gy 45 Gy
Case IMRT 3D‐CRT IMRT 3D‐CRT IMRT 3D‐CRT
1 59.77 40.39 45.31 37.47 13.27 22.95
2 63.15 48.48 53.18 45.29 24.7 34.59
3 33.8 50.52 28.42 35.67 11.51 13.67
4 51.55 66.49 38.62 60.48 12.09 18.97
5 40.06 23.51 26.23 21.06 6.81 12.98
6 33.52 35.6 27.49 22.56 6.71 5.81
7 62.24 76.01 48.41 64.84 9.4 16.26
8 40.17 52.22 25.96 34.51 5.24 13.94
9 32.65 35.51 21.8 23.66 3.68 6.56
10 56.48 46.42 44.53 37.86 7 7.5
11 50.47 63.3 38.37 44.04 12.39 20.04
12 34.84 46.23 27.48 27.71 7.78 8.24
13 24.27 32.72 19.55 24.65 5.31 8.32
14 55.41 65.59 40.25 49.36 8.35 19.34
15 17.27 23.7 10.63 11.66 1.7 3.38
16 45.24 62.93 31.08 46.54 6.85 9.88
17 58.11 69.98 40.15 54.27 8.21 24.83
18 48.62 57.02 32.35 52.77 7.69 22.49
19 60.2 73.1 44.04 51.29 16.4 23.97
20 62.9 63.86 47.41 56.19 14.39 23.05
Mean 46.54 51.68 34.56 40.09 9.47 15.84
p Value
=0.059
=0.015
<0.0001