Skip to main content
. Author manuscript; available in PMC: 2018 Dec 1.
Published in final edited form as: IEEE Trans Med Imaging. 2017 Jun 13;36(12):2524–2535. doi: 10.1109/TMI.2017.2715284

TABLE II.

Quantitative Results (Mean±SDs) Associated With Different Algorithms for the Images in the Testing Dataset

PNSR RMSE SSIM
LDCT 36.3975±5.24 0.0158±0.0062 0.8644±0.0754
TV-POCS 41.5021±2.11 0.0087±0.0010 0.9498±0.0126
K-SVD 40.8445±2.54 0.0096±0.0013 0.9447±0.0168
BM3D 41.5358±2.09 0.0088±0.0010 0.9509±0.0127
CNN10 41.9892±2.10 0.0082±0.0011 0.9658±0.0129
KAIST-Net 42.2746±2.05 0.0078±0.0009 0.9688±0.0098
RED-CNN 43.7871±2.01 0.0069±0.0007 0.9754±0.0086