Skip to main content
. Author manuscript; available in PMC: 2018 May 7.
Published in final edited form as: Phys Med Biol. 2017 Jan 31;62(9):3682–3699. doi: 10.1088/1361-6560/aa5d43

Table 1.

Average relative dose difference ∊̅D10%, range difference R, γ-test passing rates Pγ for all testing cases.

Phantom Beam
setup
Energy
(MeV/u)
∊̅D10%
(%)
R
(mm)
Pγ (1%/1mm)
(%)
Pγ (2%/1mm)
(%)
Water Pencil beam 100 0.7 <0.1 99.0 99.0
250 0.5 <0.1 99.8 99.8
400 0.9 <0.1 68.6 99.6
Broad beam 100 0.5 <0.1 99.9 100
250 0.4 <0.1 99.8 99.9
400 0.8 <0.1 93.8 98.2
Lung Broad beam 100 1.6 0.8 99.9 100
250 0.6 0.6 99.1 99.8
400 0.9 1.4 93.0 97.5
Soft tissue Broad beam 100 1.0 <0.1 99.9 100
250 0.5 <0.1 99.1 99.7
400 0.9 0.7 91.5 96.4
Bone Broad beam 100 1.0 <0.1 95.9 97.1
250 0.6 <0.1 99.7 99.9
400 0.9 <0.1 79.1 99.3
Slab Broad beam 300 0.8 NA 96.0 99.8
Patient Broad beam 250 0.5 NA 99.6 99.8