FIG. 4.
(a) We plot the error E, as defined in Eq. (74) as a function of the splitting time step Δtsplit. For the smallest time step, Δtsplit = 0.001, the error remains small for case 6 but is larger for cases 1 and 4, in which some or all of the reactions are diffusion limited. (b) The average number of S4 molecules over time in case 1. We see that the hybrid method with Δtsplit = 0.1 underestimates the average number of S4 molecules but still produces better results than with a pure mesoscopic simulation. The hybrid method matches the microscopic results closely for Δtsplit ≤ 0.01.