Skip to main content
. Author manuscript; available in PMC: 2018 Aug 9.
Published in final edited form as: Phys Med Biol. 2017 Aug 9;62(17):7056–7074. doi: 10.1088/1361-6560/aa7dc9

Table 6.

Uncertainties in ρe and Z estimation (1σ) caused by the DECT modeling uncertainty.

Method ρe estimation uncertainty (1σ) Z estimation uncertainty (1σ)

Lung (%) Soft (%) Bone (%) Lung (%) Soft (%) Bone (%)
HS 1.26 0.43 0.37 0.55 4.74 1.43
Bourque 1.46 0.70 0.44 4.81 4.33 0.70