Table 2.

Diffusion weighted experimental parameters.

Condition 1 2 3 4 5
Application Rat/Simulation Rat/Simulation Rat Rat Human
Readout PRESS PRESS EPI EPI EPI
EPI Segments 4 4 1
rFOV 2DRF 2DRF
TR (ms) 3,000 3,000 1,500 1,500 2,000
TE (ms) 41 41 61 35 86
FOV (mm2) 10 10 25.6 × 25.6 13.5 × 9.6 200
Voxel/Slice thickness (mm) 6 6 1.5 1.5 5
In-plane resolution 266 × 400μm2 150μm2 1.43 mm2
DWI Schemea 5-design DDE DDE Filter-Probe DDE Filter-Probe SDE Filter-Probe SDE Filter-Probe
DWI Acquisitions 72 36 36 36 36
Max total b-value (s/mm2) 4,000 4,000 4,000 3,000 3,000
Diffusion separation Δ (ms) 12 12 12 12 32.5
Diffusion duration (ms) 6 6 6 6 25.4
Mixing Time (τ; ms) 6 6 6
NEX 1 1 2 2 6
Acquisition Time 3:48 2:09 5:36 5:36 5:26
Outcome Measure(s) Eccentricity (μm4) ADC|| (μm2/ms) fR (fraction) ADC|| (μm2/ms) ADC||(μm2/ms) ADC|| (μm2/ms)
a

From Table 1.