TABLE 3.
Percent compliance with individual BSL-1 requirements, WCLN risk assessment survey respondents, 2016a
| Requirementb | % compliance |
|---|---|
| Laboratory design compatible with cleaningc | 89.3 |
| Hand-washing sink near laboratory exit | 89.3 |
| Effective pest management program | 82.5 |
| Decontamination of cultures and other infectious materials before disposal | 76.7 |
| Screens on windows opening to the exterior (if present) | 69.9 |
| Placement of a biohazard sign at the entrance when infectious agents are present | 61.2 |
Data are for 103 respondents.
Requirements that are not specifically listed here but that met a >90% rate of compliance among the respondents included (in order of increasing compliance) benchtops impervious to water and resistant to heat, organic solvents, and other chemicals; access to laboratory controlled by doors; safe handling of sharps; procedures to minimize splashes and/or aerosols; decontamination of work surfaces; availability of personal protective equipment; prohibition of food, drink, smoking, cosmetic application, and contact lens handling; availability of mechanical pipetting devices; and appropriate personnel training regarding duties and prevention of exposure.
Examples include nonporous chair coverings and the absence of carpets and rugs.