Skip to main content
. 2017 Dec 20;10(12):1450. doi: 10.3390/ma10121450

Table 2.

Failures rate (%) for OLD when 1–3 layers of dielectric ink are used.

Mesh (Inch) 1 Layer 2 Layers 3 Layers
Type Type Type
A B C A B C A B C
330 100 100 100 100 100 50 0 50 100
230 50 100 100 0 0 0 0 0 0
175 50 100 100 0 0 0 0 0 0
137 100 100 50 0 0 0 0 0 0
123 50 50 50 0 0 0 0 0 0