Skip to main content
. 2017 Dec 11;6:e32337. doi: 10.7554/eLife.32337

Table 1. Intrinsic electrophysiological properties of Sst-INs, FS-INs, and PCs in visual cortex.

Postnatal day Rin (MΩ) Threshold (mV) Amplitude (mV) Half-width (ms) AHP (mV)
Sst-IN P12-13 (n = 46) 430.2 ± 33.3 −51.7 ± 1.0 60.6 ± 0.9 2.46 ± 0.10 10.6 ± 0.4
P14-15 (n = 27) 332.6 ± 26.6 −52.6 ± 1.3 61.0 ± 1.1 1.76 ± 0.16*** 11.1 ± 0.5
P17-20 (n = 30) 367.9 ± 27.9 −53.7 ± 1.4 60.0 ± 0.9 1.52 ± 0.07*** 10.6 ± 0.5
FS-IN P12-13 (n = 45) 201.8 ± 11.9 −44.0 ± 0.8 48.1 ± 0.8 1.45 ± 0.05 19.0 ± 0.3
P14-15 (n = 18) 113.0 ± 8.7*** −45.0 ± 1.4 47.0 ± 1.1 1.03 ± 0.04*** 18.4 ± 0.5
P17-20 (n = 29) 126.9 ± 8.5*** −43.9 ± 1.0 49.4 ± 0.8 0.86 ± 0.04*** 19.8 ± 0.4
PC P12-13 (n = 32) 326.6 ± 20.6 −46.1 ± 1.3 63.8 ± 0.8 4.08 ± 0.13 11.4 ± 0.3
P14-15 (n = 15) 214.0 ± 12.2*** −47.8 ± 1.8 65.6 ± 0.9 3.86 ± 0.30 11.5 ± 0.8
P17-20 (n = 29) 212.4 ± 13.6*** −48.0 ± 1.2 68.8 ± 1.0*** 3.45 ± 0.20** 12.1 ± 0.4

**p<0.01; ***p<0.001. P14-15 and P17-20 groups were compared with the P12-13 group.