We thank Drs. Gawda and Czarnik for their comments [1] regarding our article on ultrasound (US)-guided central venous catheter (CVC) placement [2].
We recommended a “six-step-approach”. Because US is still used infrequently for CVC insertion [3, 4] we aimed to provide a basic, pragmatic, and evidence-based concept applicable in clinical routine rather than making the approach unnecessarily complicated.
We discussed that a disadvantage of the short-axis/out-of-plane approach is that not the entire needle but only an echogenic point (that must not be the needle tip) is visualized [2].
Experienced users might perform additional steps during US-guided CVC placement, e.g., double-checking that the needle is not localized over the adjacent artery before entering the target vein (long-axis/in-plane approach). Although this additional step might further improve procedural quality in the hands of experts, it is not backed up by study data and necessitates transiently abandoning the view of the needle and the target vein. This “angle change” of the US probe to check the adjacent artery before puncturing the vein only makes sense if the artery is anatomically located equally deep or deeper (and not more superficial) compared to the vein.
US can provide important information about the correct position of the guidewire [2]. As suggested, one can check the ipsilateral subclavian vein (for internal jugular vein CVCs) or the internal jugular vein (for subclavian CVCs) to exclude misdirection of the guidewire. Consequently, following this line of argument, one should also exclude misdirection of the guidewire in the contralateral veins and the thyroid veins. It needs to be emphasized, however, that strictly aseptic conditions need to be ensured during all additional steps; this might even require a second operator excluding misdirection of the guidewire in different veins with an additional non-sterile US probe. Alternatively, one could confirm the tip of the guidewire in the superior vena cava/the right atrium using transthoracic echocardiography.
Although not part of our basic recommendations, experienced operators can use US to confirm the correct position of the CVC (direct visualization of the CVC tip or indirect identification of the CVC tip by rapid injection of saline and imaging of turbulent flow in the right atrium or vascular structures) and to exclude iatrogenic pneumothorax [5].
US offers various opportunities to improve the quality and safety of CVC placement, but to advocate and promote US as the standard of care for CVC placement in anesthesiology and critical care our recommendations need to be straightforward!
Acknowledgements
None.
Funding
None.
Availability of data and materials
Not applicable.
Abbreviations
- CVC
Central venous catheter
- US
Ultrasound
Authors’ contributions
BS, LS-U, TWLS, and JLT conceived the article, performed the literature search, drafted the manuscript, and read and approved the final manuscript.
Ethics approval and consent to participate
Not applicable.
Consent for publication
Not applicable.
Competing interests
The authors declare that they have no competing interests.
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Footnotes
See related letter by Gawda and Czarnik, https://ccforum.biomedcentral.com/articles/10.1186/s13054-017-1877-9
This reply refers to the comment available at: https://doi.org/10.1186/s13054-017-1877-9.
Contributor Information
Bernd Saugel, Phone: 0049 40 7410 18866, Email: bcs.muc@gmx.de, Email: bernd.saugel@gmx.de.
Leonie Schulte-Uentrop, Email: l.schulte-uentrop@uke.de.
Thomas W. L. Scheeren, Email: t.w.l.scheeren@umcg.nl
Jean-Louis Teboul, Email: jean-louis.teboul@aphp.fr.
References
- 1.Gawda R, Czarnik T. A systematic approach to the ultrasound-guided central venous catheter placement—desirable modifications. Crit Care. 2017. In press. [DOI] [PMC free article] [PubMed]
- 2.Saugel B, Scheeren TWL, Teboul JL. Ultrasound-guided central venous catheter placement: a structured review and recommendations for clinical practice. Crit Care. 2017;21:225. doi: 10.1186/s13054-017-1814-y. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Maizel J, Bastide MA, Richecoeur J, Frenoy E, Lemaire C, Sauneuf B, Dupont H, Tamion F, Nseir S, Du Cheyron D. Practice of ultrasound-guided central venous catheter technique by the French intensivists: a survey from the BoReal study group. Ann Intensive Care. 2016;6:76. doi: 10.1186/s13613-016-0177-x. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Soni NJ, Reyes LF, Keyt H, Arango A, Gelfond JA, Peters JI, Levine SM, Adams SG, Restrepo MI. Use of ultrasound guidance for central venous catheterization: a national survey of intensivists and hospitalists. J Crit Care. 2016;36:277–83. doi: 10.1016/j.jcrc.2016.07.014. [DOI] [PubMed] [Google Scholar]
- 5.Ablordeppey EA, Drewry AM, Beyer AB, Theodoro DL, Fowler SA, Fuller BM, Carpenter CR. Diagnostic accuracy of central venous catheter confirmation by bedside ultrasound versus chest radiography in critically ill patients: a systematic review and meta-analysis. Crit Care Med. 2017;45:715–24. doi: 10.1097/CCM.0000000000002188. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
Not applicable.