Skip to main content
. 2017 Nov 24;17(12):2713. doi: 10.3390/s17122713

Table 2.

Comparison of the characteristics of the proposed sensor and other recently published microwave microfluidic sensors with resonance shift operating principle.

Reference fmin (GHz) fmax (GHz) εmin εmax Sensitivity (MHz/Relative Epsilon) Overall Size (λg × λg)
[6] 14.05 17.08 1 80.1 38.35 0.5 × 0.5
[8] 8.9 10.5 1 80.1 20.25 5.8 × 5.8
[9] 3.4 4.2 1 80.1 10.13 0.23 × 0.22
[10] 0.915 1 1 80.1 1.07 0.19 × 0.08
[15] 1.57 1.875 16.5 72 5.5 0.1 × 0.1
[23] 1.18 1.52 1 80.1 4.3 0.086 × 0.094
This work resonance 1 1.703 1.984 1 80.1 3.57 0.21 × 0.17
This work resonance 2 3.072 3.381 1 80.1 3.91