Authors |
Task |
Frequency |
Intensity |
Electrodes position |
Results |
Feurra et al., 2011 |
measurements of corticospinal excitability at rest |
5 Hz, 10 Hz, 20 Hz, 40 Hz |
1 mA |
Left M1, parietal cortex, ulnar nerve |
20 Hz increased MEPs size at rest |
Feurra et al., 2013 |
measurements of corticospinal excitability at rest and during motor imagery |
5 Hz, 10 Hz, 20 Hz, 40 Hz |
1 mA |
Left M1 |
20 Hz increased MEPs size at rest while 5 and 10 Hz increased MEPs size during motor imagery |
Cancelli et al., 2015 |
measurements of corticospinal excitability at rest |
20Hz |
2.2 mA |
Bilateral M1 |
Differences in cortical excitability enhancement with respect to personalized and non-personalized electrodes |
Guerra et al., 2016 |
measurements of corticospinal excitability at rest |
7 Hz, 20 Hz |
1 mA |
Left M1 |
20 Hz tACS modulated SICI, ICF and SAI |