Table 6. Activation dynamics variables.
Par./current | units | Na | Kdr | KM | KA | CaT | CaL | CaN | BK | IH |
---|---|---|---|---|---|---|---|---|---|---|
α | 3 | 1 | 1 | 4 | 2 | 2 | 2 | 1 | 1 | |
Vm | (mV) | -34.77 | -15 | -30 | -57 | -54.15 | -20 | -10 | -20 | -80 |
km | 10.5 | 7 | 9 | 8.5 | 6.2 | 8.4 | 7 | 2 | 5 | |
am | 0.05 | 1 | 100 | 0.37 | 0.7 | 0.5 | 1 | 2 | 900 | |
bm | 0.15 | 4 | 0 | 2 | 13.5 | 1.5 | 1.5 | 0 | --- | |
Vτm | (mV) | -43 | -20 | --- | -55 | -76 | -20 | -15 | --- | -80 |
Activation parameters for each current: number of gates, αi, half-activation voltage, Vm, activation slope factor, km, and specific parameters for the time constant function am, bm, Vτm. These values were taken from ref [42]. Where no unit is specified, parameters are unit-less values. Abbreviations for currents are as in Eq 2.