Impact Insertion of Osteochondral Grafts: Interference Fit and Central Graft Reduction Affect Biomechanics and Cartilage Damage

Alvin W Su a,d, Yunchan Chen a, Dustin H Wailes a, Van W Wong a, Shengqiang Cai b,d, Albert C Chen a, William D Bugbee e,f, Robert L Sah a,c,d
PMCID: PMC5756525  NIHMSID: NIHMS900294  PMID: 28682003

Abstract

An osteochondral graft (OCG) is an effective treatment for articular cartilage and osteochondral defects. Impact of an OCG during insertion into the osteochondral recipient site (OCR) can cause chondrocyte death and matrix damage. The aim of the present study was to analyze the effects of graft-host interference fit and a modified OCG geometry on OCG insertion biomechanics and cartilage damage. The effects of interference fit (radius of OCG – radius of OCR), loose (0.00mm), moderate (0.05mm), tight (0.10mm), and of a tight fit with OCG geometry modification (central region of decreased radius) were analyzed for OCG cylinders and OCR blocks from adult bovine knee joints with an instrumented drop tower apparatus. An increasingly tight OCG-OCR interference fit led to increased taps for insertion, peak axial force, graft cartilage axial compression, cumulative and total energy delivery to cartilage, lower time of peak axial force, lesser graft advancement during each tap, higher total crack length in the cartilage surface, and lower chondrocyte viability. The modified OCG, with reduction of diameter in the central area, altered the biomechanical insertion variables and biological consequences to be similar to those of the moderate interference fit scenario. Micro-computed tomography confirmed structural interference between the OCR bone and both the proximal and distal bone segments of the OCGs, with the central regions being slightly separated for the modified OCGs. These results clarify OCG insertion biomechanics and mechanobiology, and introduce a simple modification of OCGs that facilitates insertion with reduced energy while maintaining a structural interference fit.

Keywords: Articular Cartilage, Cartilage Mechanics, Impact Mechanics, Osteochondral Autograft, Osteochondral Allograft

Introduction

Repair with osteochondral graft (OCG) is one of the most effective surgical treatments for focal articular cartilage defects.1,2 However, during insertion, impact loads are applied to the articular cartilage (AC) of the OCG and may result in chondrocyte death.3 Viable chondrocytes and cartilage matrix integrity are important for clinical success of the surgery.4,5 Typically, such OCG are prepared to be cylindrical, as are the osteochondral recipient (OCR) sites.

The biomechanics during the OCG insertion process reflect a series of impact events. The surgeon applies taps (N total) to insert the OCG into the OCR. For each tap (i), the peak force (Fpi) increases as the OCG advances deeper.6,7 Fpi increases substantially as the OCG is seated and bottoms out,6,8 particularly for shorter OCGs that have relatively high structural stiffness.9 The duration of each tap (Ti) is brief, ranging from 0.5 to 5 ms.3,5,7,8 However, the distribution of the impact energy delivered to the graft, as well as the resultant cartilage compressive strain and extent of OCG advancement, have not been reported.

Understanding the mechanobiology of AC damage is important for preserving graft tissue health during surgery. Damage to the AC during OCG impact has been related to a variety of biomechanical factors. During OCG insertion, chondrocyte death has been associated with Fpi.6,8 For non-insertional impact scenarios, chondrocyte death has been associated with impact force,8 contact stress,10,11 compressive stress rate,12,13 compressive strain,10,14 compressive strain rate,15 and total impact energy.1618 Articular cartilage failure has been described by fracture energy, or the energy normalized to crack area,19 so that the parameter of energy input, or energy normalized to cartilage area, may provide an index related to cartilage damage.

The graft-host interference fit (radius of OCG – radius of OCR, ΔR) between OCG and OCR is one of the key parameters for surgical instrument design. Studies of analogous situations have assessed the effect of ΔR on insertion mechanics. Analogously, when nails are driven into wood, Fpi increases with nail diameter.20 While a relatively tight fit can be beneficial to graft-host healing due to increased post-insertional graft stability, such a tight fit requires relatively high impact to achieve the insertion. The effect of ΔR on OCG insertion biomechanics and resultant cartilage damage remains to be elucidated.

The hypotheses of the present study were that during OCG insertion into OCR, (a) increasing tightness of graft-host interference fit leads to higher insertion energy and resultant AC damage, and (b) a modified OCG geometry alters the mechanics of impact insertion and therefore reduces insertion energy and resultant AC damage. The specific aims were to determine the effect of ΔR for standard cylindrical OCG and OCR on (1) insertion biomechanics and (2) damage to AC cells and tissue, and also (3) to compare standard OCG and modified OCG for insertion biomechanics and the resultant AC damage.

Materials and Methods

Study Design

Study 1

The effects of ΔR on biomechanics of insertion and damage to articular cartilage were assessed in terms of the total number of taps (N), cumulative energy density delivered to cartilage of OCG (ΣWS,iOCG), and viability of chondrocytes at the articular surface (VAC,OCG), as well as the relationship between cumulative OCG advancement (uadv[m]) and energy delivered (WTamp[m]) after the mth tap for standard cylindrical OCG and OCR with three study groups: (1) loose fit, ΔR = 0.00 mm (n=7), (2) moderate fit, ΔR = 0.05 mm (n=6), and (3) tight fit, ΔR = 0.10 mm (n=6).

Study 2

The effect of OCG geometry on insertion biomechanics and articular cartilage damage was assessed by comparing the last group in Study 1 to an additional group, also with original ΔR = 0.01 mm, but with modified OCG geometry as described below to have a reduced ΔR in a central region (n=7).

Detailed Experimental Methods

Sample Preparation

A total of 41 OCGs and 26 OCRs were prepared from the distal femora of six adult bovine knees, obtained fresh from an abattoir within 24 hours of sacrifice and using sterile technique. With a coring bit and diamond-edged saw, OCGs were prepared to a radius of 2.40 mm and to a subchondral bone height of 5.00 mm. The OCRs were prepared as osteochondral cuboid blocks with a base of ~15 mm × 15 mm, and height of ~15 mm. Of the 41 OCGs, 15 served as control samples without any impact loading treatment. In Study 1, 19 OCGs were used. In Study 2, seven OCGs were prepared to a modified geometry. During OCG and OCR preparation, all samples were kept moist and cool by irrigation with phosphate buffered saline (PBS).

Graft-host Interference Fit (ΔR)

was calculated as the radius of the OCG (2.40 mm) minus the radius of the OCR (aOCR). The recipient sites were drilled in the center of the cuboid blocks to a depth of 10 mm from the articular surface using stainless steel drill bits of 4.80, 4.70 and 4.60 mm in diameter. Therefore, aOCR values were 2.40, 2.35 and 2.30 mm, respectively, and the resulting three levels of ΔR were 0.00, 0.05 and 0.10 mm (Fig. 1A, 1C).

Figure 1. Schematic of geometries of OCG and OCR.

Figure 1

(A) standard OCG, (B) modified OCG, and (C) OCR. Indicated is graft-host interference fit (ΔR).

OCG with modified geometry

Starting from the standard OCG, a central region with decreased radius was created. Specifically, a ~0.25 mm reduction in radius was created in a 2 mm long (deep) region, extending down from 1.5 mm below the cartilage-bone junction (Fig. 1B). This was achieved by holding the OCG in a collet (diameter 4.8 mm) of a mill machine, and then gradually translating a 2 mm-thick rectangular hand file, mounted on the platform of the drill mill, for 0.25 mm after initial contact. During this process, the sample was irrigated with PBS to cool and hydrate the tissue. In addition, care was taken to not disturb the articular surface.

OCG Insertion

Standard and modified OCG were inserted in a standardized way, applying a prescribed energy density, WS,iPE, for each tap i and recording the resultant impact load, Fi(t), the movement of the cartilage surface, uiTamp(t), and the OCG advancement distance with each tap, uadvi. The OCG was pre-inserted manually, past the AC, seating it at the bone, ~1.5 mm into the OCR. A rigid tamp was then placed atop the AC surface. Serial taps were applied to the OCG via the rigid tamp, using a drop tower apparatus instrumented with a load sensor at the impaction surface, providing Fi(t), and a laser displacement sensor assessing the position of the articular surface of the OCG via the tamp, providing uiTamp(t). After each tap, a side-view digital photograph (0.02 mm pixel resolution) was taken to allow measurement of the cumulative OCG advancement distance after tap i, uadv[m], and from these, the incremental OCG advancement distance, uadvi, for each tap. The applied energy density, energy / OCG cartilage area, of each tap i, WS,iPE, was set by using a weight at various heights (with potential energy that is the product of mass, acceleration due to gravity, and height) from the OCG bone surface. The first tap had WS,1PE of 0.9 mJ/mm2. Successive taps had energy density increasing by a factor of 1.5, so that WS,iPE = 0.9×1.5(i−1) mJ/mm2. Successive taps were applied until tap N, after which the articular surface of the OCG was flush with that of the OCR (Fig. 2A).

Figure 2. Schematic of impact insertion of OCG and mechanical variables and parameters.

Figure 2

(A) Advancement of OCG into OCR, starting with flush position (A1), advancing with successive taps (A2–5), to final flush position (A5). Tap #, i, out of N total taps. Peak tamp advancement with tap i, up,iTamp. OCG (bone base) advancement with tap i, uadvi, and overall advancement at full insertion, uadvinsert. (B) OCG at five successive insertion positions, at insertion depths of 1–5 mm (B2–B6), at which parameters were estimated.

Chondrocyte Viability Analysis

After the final impact, the articular cartilage was analyzed for percentage of viable chondrocytes.3,21 The articular cartilage of the OCG was sliced off as a disc with a sterile scalpel and incubated for 24 hrs in medium with 10% FBS. The disc was then stained with LIVE/DEAD® (Thermo Fisher) as previously described,21 imaged en face with fluorescence microscopy in the central (3.75 mm × 0.75 mm) area, spanning most of the sample. Image processing was performed to determine viability, VAC,OCG, as live cells / (live cells + dead cells).

Articular Cartilage Surface Analysis

Finally, matrix damage was assessed by determining Lcrack, the total length of cracks at the articular surface, and the post-impact articular cartilage surface area, AAC,OCS(t24hr+). Samples were stained with India Ink and photographed.22 Using NIH ImageJ software, both edges of each crack were traced, and the total edge lengths were summed. Lcrack was taken as half of the total edge length. The total surface crack length of each OCG was determined as the average of measurements by three independent observers. The measurement was highly reproducible, with intra-observer correlation coefficient of 0.98. In addition, AAC,OCS(t24hr+) was measured as the area of the articular cartilage surface using ImageJ.

Micro-computed tomography (µCT) imaging

One sample of each experimental group was chosen for µCT scanning for qualitative assessment of the top, middle and bottom parts of graft-host subchondral bone interface. The µCT scan settings were those described previously with (9 µm)3 voxel resolution.4

Biomechanics Calculations

All biomechanical variables and parameters are listed in Table 1. Mechanical variables were quantified from Fpi(t), uiAC,OCG(t), and uadvi. Peak contact stress (σpi) was calculated as the peak contact force (Fpi) normalized to the surface area of the OCG (AOCG, 18.09 mm2). Impact impulse (ICi) was quantified by integrating impact force over time for the duration (Ti) of the impact. Peak axial displacement of AC of OCG (up,iAC,OCG) was taken as peak axial displacement of the tamp (up,iTamp) minus the OCG advancement distance during for each tap (uadvi). Peak axial strain of the AC of OCG, εpi, was calculated by normalizing up,iAC,OCG to the AC thickness of the OCG (hAC,OCG). For each tap i, the energy delivered by the tamp to the sample, WiTamp, was calculated by integrating Fi(t) over the axial displacement of the tamp, uiTamp(t). Energy delivered to the AC of the OCG, WiOCG and to advancing the OCG into OCR, Wiadv, were determined by an energy balance. For each tap, i, WiTamp was assumed to be divided into WiOCG and the work to advance the OCG into the OCR, and accordingly apportioned to the cartilage by the peak deformation of AC of OCG relative to the movement of bone, with WiOCG = WiTamp • (up,iAC,OCG / up,iTamp), and Wiadv = WiTamp • (uadvi / up,iTamp). (Fig. 2A) The corresponding energy density delivered to the AC of an OCG by tap i, WS,iOCG, was calculated by normalizing WiOCG to AOCG. The energy density delivered to the bone interface for OCG advancement into OCR, WS,iadv, was calculated by normalizing Wiadv to the increment in host-graft bone interface area, Aadvi, encompassing the OCG travel distance uadvi, so that Aadvi = π × 4.80 mm × uadvi. Cumulative energy delivered to OCG samples through tap m, WTamp[m], was calculated as i=1mWiTamp. Cumulative energy density delivered to the articular cartilage through tap m was calculated as i=1mWS,iOCG

Table 1.

Biomechanical parameters and variables.

parameter definition unit
AOCG articular cartilage surface area of OCG mm2
aOCR radius of OCR mm
hAC,OCG thickness of AC of OCG prior to impact mm
i sequential tap # number to impact insert OCG into OCR, i=1,2,…,N tap #
WS,iPE applied energy density for tap #i mJ/mm2
variable definition unit
Aadvi increment in host-graft bone interface area between OCG and OCR during tap #i mm2
F(t) contact force applied on the tamp N
Fpi peak force applied on the tamp during tap #i N
Ici impact impulse of the impact event of tap #i N•ms
Lcrack total crack lengths on articular cartilage surface of OCG mm
Ti impact time duration during tap #i ms
t relative timeframe for impact event ms
uadvi OCG advancement distance after during tap #i mm
uadvinsert overall advancement at full insertion mm
uadv[m] cumulative OCG advancement distance after tap #m mm
uiTamp(t) axial displacement of the tamp during tap #i mm
up,iAC,OCG peak axial compressive displacement of AC of OCG during tap #i mm
up,iTamp peak axial displacement of the tamp during tap #i mm
VAC,OCG surface chondrocyte viability of AC of OCG after insertion %
Wiadv energy advancing OCG into OCR during tap #i mJ
WinsertAC,OCG total energy delivered to AC of OCG mJ
WiOCG energy delivered to AC of OCG during tap #i mJ
WiTamp energy delivered by the tamp to the sample during tap #i mJ
WTamp[m] cumulative energy delivered by the tamp to the sample after tap #m mJ
WS,iOCG energy density delivered to AC of OCG during tap #i mJ/mm2
WS,jadv sectional energy density of OCG advancement for section #j mJ/mm2
εpi peak axial strain of AC of OCG during tap #i mm/mm
ΣWS,iOCG cumulative energy density delivered to AC of OCG mJ/mm2
σpi peak contact stress during tap #i MPa

In Study 2, the energy associated with each 1mm of OCG travel into the OCR was calculated to allow overall assessment of the tapered geometry, since the OCG samples advanced to a different extent during the successive taps. To do so, analysis was performed for advancement in five sequential 1 mm sections, j = i, ii, …, v, with the first portion starting at 0 in the z axis. Thus, for each section, the graft-host interface area was 15.08 mm2 (Fig. 2B). The sectional energy density of OCG advancement (WS,jadv) was calculated as the sum of weighted Wiadv values for each section j, partitioning the Wiadv of each tap according to the OCG travel distance within each section. For example, if during tap #m, the OCG advanced 1.5 mm, through the final 0.2 mm in section #ii, all the way (1.0 mm) through section #iii and then into the beginning 0.3 mm into section #iv, then (0.2/1.5)Wmadv was taken to contribute to WS,iiadv, and (0.3/1.5)Wmadv to WS,ivadv, with WS,iiiadv = (1.0/1.5)Wmadv.

Statistical Analysis

The effects of ΔR (0.00, 0.05, 0.10 mm, and 0.10 mm with modified OCG geometry) on ΣWS,iOCG, N, VAC,OCG and Lcrack were assessed using one-way ANOVA with Tukey post-hoc test. The effects of ΔR on Fpi, σpi, ICi, Ti, up,iTamp, up,iAC,OCG, uadvi, εpi, WS,iTamp, WS,iOCG, WS,iadv were assessed using one-way ANOVA for the first eight taps (1 ≤ i ≤ 8) where data was recorded for more than two groups, and unpaired two-tailed student t test for 9 ≤ i ≤ 10 where data was from the two groups with tight fit (ΔR = 0.10 mm, with vs. without modified OCG geometry). In addition, the effect of OCG geometry modification, which was ΔR = 0.10 mm, with vs. without modified OCG geometry, on WS,jadv of each section #j, were assessed using unpaired two-tailed student t test. The relationship between Lcrack and ΣWS,iOCG for all OCG samples in both studies was assessed by linear regression. Data are expressed as mean±SD. Significance was set at α=0.05.

Results

Study 1

Tighter interference fit resulted in more total tap numbers and higher cumulative energy density delivered to the AC of the OCG by the completion of insertion (Table S-1, Fig. 3A–B). Compared to the loose fit group, ΔR = 0.00 mm, the tight fit group, ΔR = 0.10 mm, required two times more taps (4.4 vs 9.7, Fig. 3A) and 25 times higher WinsertAC,OCG (53 mJ vs 927 mJ, Fig. 3B) and thus higher ΣWS,iOCG. When looking at uadv[m] as a function of log(WTamp[m]), tighter interference fit presented a “right-shift” phenomenon of the sigmoid curve (Fig. 3D). This indicated that more energy was delivered to reach the same level of OCG advancement into the OCR.

Figure 3. Effects of interference fit (ΔR) and OCG geometry modification on insertion mechanics.

Figure 3

(A) Total number of taps (N). (B) Total energy delivered to AC of OCG (WinsertAC,OCG). (C) Viability of surface chondrocytes (VAC,OCG). (D) Cumulative OCG advancement (uadv[m]) as a function of cumulative insertion energy (WTamp[m]), after each tap, i, as labeled.

During the initial insertion taps, tighter interference fit led to higher Fpi, σpi (taps #1–3), WS,iOCG (taps #2–4), and WS,iadv (tap #2), as well as shorter Ti (tap #1, 3, 4) and lower uadvi (tap #1, 2, 4). WS,iTamp, up,iAC,OCG, ICi, and εpi were generally similar among loose, moderate, and tight fit groups (Fig. 4A–C, Table S-1).

Figure 4. Typical effects of interference fit (ΔR) and OCG geometry modification on impact mechanics and cartilage damage.

Figure 4

(i–iv) Study Groups are standard OCG geometry with OCR that generate (i) loose, (ii) moderate, and (iii) tight interference fits, and (iv) modified OCG geometry into OCR with tight fit. (A–C) Mechanics of OCG insertion. For 4th tap, time courses of measured (A) tamp contact force, (B) tamp displacement and (C) parametric plot of tamp contact force and displacement, illustrating energy-associated loop. In (B) are indicated peak tamp advancement increment, divided amongst OCG advancement, uadv[4], and deduced cartilage compaction, upAC,OCG[4]. In (C) are indicated delivered energy values. (D–F) En face microscopic analysis of effects on cartilage. (D) Reflected light view of articular surface after India Ink staining, showing cartilage damage and cracks. Fluorescence view of articular surface after Live-Dead fluorescence staining, with (E) live cell indicator in green, and (F) dead cell indicator in red.

Tighter interference fit resulted in more surface chondrocyte death and cartilage tissue cracks in the OCG (Fig. 3C, Fig. 4D–F). The mean values of VAC,OCG were 98%, 94%, 83%, 57% for no load control, loose, moderate and tight fit groups, respectively.

Study 2

Modification of OCG geometry resulted in fewer total tap numbers and lower cumulative energy delivered to AC of OCG by the completion of insertion (Fig. 3A–B). The mean value of N decreased from 9.7 to 7.6, and ΣWS,iOCG decreased 72%. When considering Σuadvi as a function of WTamp[m] (on a log scale), OCG geometry modification led to a “left-shift” of the sigmoidal curve (Fig. 3D).

At the middle part of insertion, modified OCG geometry led to lower WS,iOCG (taps #4–6) as well as higher up,iTamp, and uadvi (tap #6 for both). The other mechanical variables were generally similar (Fig. 4A–C, Table S-1).

Surface chondrocyte death and cartilage tissue cracks were less among modified OCG (Fig. 3C, Fig. 4D–F). The mean value of VAC,OCG for modified OCG was 76% compared to 57% for non-modified OCG.

OCG geometry modification resulted in less sectional energy density of OCG advancement in the middle part of insertion. Modified OCGs had lower WS,iiadv, WS,iiiadv, WS,ivadv compared to non-modified OCGs. WS,iadv, WS,vadv were not different between the two groups (p=0.52 and 0.06, respectively), but the mean value of WS,vadv was lower for modified OCG (Fig. 5).

Figure 5. Effect of OCG geometry modification on energy for OCG advancement to defined depths.

Figure 5

Data of cumulative energy after individual taps was interpolated to estimate values at the indicated positions of 0–5 mm insertion depth.

Lcrack was strongly correlated with WinsertAC,OCG and therefore ΣWS,iOCG (R2=0.93, p<0.0001, Fig. 6). The mean value of Lcrack of tight fit group was 11.58 mm, ~100-fold that (0.11 mm) of the loose fit group, and ~6-fold that (2.04 mm) with OCG geometry modification.

Figure 6. Correlation analysis of total crack length on graft cartilage surface (Lcrack) with total energy delivered to AC of OCG (WinsertAC,OCG).

Figure 6

Data for all samples, with loose, moderate, and tight interference fits of standard samples, and also tight interference fit of modified samples are indicated with colored symbols.

Qualitatively, µCT showed differences in interference fit (Fig. 7). The tight fit sample presented the most apparent subchondral bone compaction at the graft-host interface. In the loose fit sample, some empty space (devoid of bone) was visible at the graft-host interface. Such space was less for the moderate fit sample, and least for the tight fit sample. The modified OCG sample exhibited a clearly visible space without subchondral bone contact at the offset middle part of the graft, and patterns similar to the non-modified sample at top and bottom of the graft.

Figure 7. Qualitative µCT assessment of subchondral bone compaction at graft-host interface after OCG insertion.

Figure 7

(A–L) µCT image slices were selected from (A–D) Upper, (E–H) Middle and (I–L) Lower portion of the graft-host subchondral bone interface, in (i–ii) Axial and (iii–iv) Sagittal orientations. Study Groups are standard OCG geometry with OCR that generate (A, E, I) Loose, (B, F, J) Moderate, and (C, G, K) Tight interference fits, and (D, H, L) Modified OCG geometry into OCR with tight fit. Yellow light box in (i) and (iii) indicates the zoom-in area of interest in (ii) and (iv), respectively.

Discussion

The present study indicates that small variations in graft-host interference fit can markedly affect the biomechanics of OCG insertion and the resultant health of, or extent of damage to, the articular cartilage. Tighter OCG-OCR fit resulted in more taps and more insertion energy for insertion as well as more cell death. With the same graft-host fit, modification of the OCG subchondral bone geometry to reduce the interference in the central part of the graft, leaving the proximal and distal region with the same interference fit, reduced the insertional energy and subsequent damage to the articular cartilage. These results thus provide important considerations about the graft-host interference fit for design of surgical methods and instruments that achieve impact insertion of osteochondral grafts, while preserving the health of the grafted articular cartilage.

The design of the present study involved a number of tradeoffs. Osteochondral tissue from the adult bovine distal femur was used as a model system, providing mature articular cartilage that is consistently healthy although different from human articular cartilage. Compared to human articular cartilage in the distal femur, bovine articular cartilage is thinner (hAC,OCG of 1.5mm in the present study versus 2.2–2.5 mm in human23,24); both human and bovine cartilage exhibit a range of depth-varying compressive moduli and stiffness depending on geometry and loading condition (e.g., 0.3–49 MPa25,26 and 3.1–13.0 MPa2729). The subchondral bone of adult bovines can be as high as 10 GPa,30 markedly higher than that ~1 GPa, of humans.31 In addition, the OCG were small in diameter compared to those used clinically (diameter of OCG autografts up to 10.0 mm and of OCG allografts typically up to 15.0 mm or more32,33.) in order to generate reasonable numbers of samples for statistical purposes. In addition, the ΔR can have a range of values for different instrumentation systems. In the present study, the diameter of OCGs was 4.8 mm, and the largest ΔR was 0.1 mm. The present study utilized bovine tissue to validate the experimental methodologies and address the scientific questions and practical problems of OCG insertion. Also, the strong correlation of ΣWS,iOCG with cartilage tissue damage may be translated to different sizes of osteochondral samples.34

In addition, at completion of insertion, a gap was left between the base of OCG and the bottom of the OCR to facilitate biomechanical analysis. Such a gap is not typical in clinical practice but allowed the experimental design of the present study to focus on the process of graft advancement into the recipient site. In certain practical scenarios (if the graft is “proud”), impact load might be applied, even when the base of the OCG is in contact with the bottom of the OCR, in order to “bottom out” the graft. This issue was not addressed in the present study, as such loading is associated with high insertional loads and cell death.8

There are a variety of graft-host interface interactions that likely account for the higher insertion energy required for tight fit samples. During each tap, the applied impact energy was partitioned to two major components: the AC of OCG, and the OCG-OCR subchondral bone system. Using a simplified model of two materials connected in series, mechanical analyses indicated that more energy is partitioned into the component with the lower stiffness. As the OCG advances further into the OCR, the subchondral bones of both can undergo elastic and plastic deformations, as well as trabecular fracture at the contact interface. The magnitude of the above increases with increasing graft-host interference fit, thus resulting in a higher equivalent stiffness. Therefore, with the same WS,iPE, higher ΔR led to higher WS,iOCG and less uadvi. Consequently, the tight fit group required more taps with higher ΣWS,iOCG to complete the insertion, and resulted in more damage to the articular cartilage.

The modification of OCG geometry decreased the equivalent stiffness of the graft-bone subchondral bone system by reducing the graft-host interface contact area. This was indicated by the lower WS,jadv in the modified OCG group when the OCG subchondral bone advanced into the OCR (j = ii to iv). Clinically, from the perspective of bone fracture fixation, osseous healing can occur with such offset space even with certain magnitude of graft-host relative motion.35

The effects of ΔR and OCG geometry modification on graft stability after insertion have yet to be elucidated. Graft stability may be modulated by graft length and diameter, as well as repeated insertion, as quantified by the pull-out load.36 However, in vivo after surgery, the OCG and OCR sustain repetitive compressive and shear loads, so that a variety of mechanical indices of stability are of interest. While the results of the present study indicate that lower ΔR facilitates OCG insertion with less impact energy, such ΔR may also predispose an OCG to excessive micro-motion and loosening.

In conclusion, the present study provided new information about the effect of graft-host interference fit on OCG insertion biomechanics and its biological consequences. The optimal graft-host interference fit thus depends upon the delicate balance between preserving graft cartilage health and adequate post-insertional graft stability. Based on the foundations of these findings, further investigation can be carried out toward clinical translation. The OCG geometry modification may improve this balance, mitigating injury to graft cartilage while restricting lateral motion with a relatively larger ΔR and tighter fit at proximal and distal portions of the graft. Investigation of other OCG-OCR heights and ΔR would be useful to further characterize the geometry modification.

Supplementary Material

Supp TableS1

Acknowledgments

Funding was from NIH RO1 AR055637 (WDB), NIH R01 AR044058 (RLS), NIH PO1 AG07996 (RLS). National Yang-Ming University, Taiwan (AWS). Potential Conflicts of Interest are the following. Board Membership: Orthopaedic Research Society (RLS); Consultancy: Joint Restoration Foundation (WDB). Stock or Stock Options. GlaxoSmithKline (RLS), Johnson and Johnson (RLS), Medtronic (RLS), Moximed (WDB), OrthAlign (WDB). Consultancy: Joint Restoration Foundation (WDB), a nonprofit tissue bank and distributor of osteochondral allografts, DePuy (WDB), Organogenesis (WDB), OrthAlign (WDB). Intellectual Property Royalties: DePuy (WDB), Smith & Nephew (WDB), Zimmer Biologics (WDB).

Footnotes

Author Contribution Statement: All authors were significantly involved in study design, execution of experiments, data analysis and manuscript preparation. All authors concur with the content and approved the final submission of the present manuscript.

References

  • 1.Hangody L, Vasarhelyi G, Hangody LR, et al. Autologous osteochondral grafting--technique and long-term results. Injury. 2008;39(Suppl 1):S32–39. doi: 10.1016/j.injury.2008.01.041. [DOI] [PubMed] [Google Scholar]
  • 2.Cole BJ, Pascual-Garrido C, Grumet RC. Surgical management of articular cartilage defects in the knee. J Bone Joint Surg Am. 2009;91:1778–1790. [PubMed] [Google Scholar]
  • 3.Borazjani BH, Chen AC, Bae WC, et al. Effect of impact on chondrocyte viability during the insertion of human osteochondral grafts. J Bone Joint Surg Am. 2006;88:1934–1943. doi: 10.2106/JBJS.E.00992. [DOI] [PubMed] [Google Scholar]
  • 4.Pallante-Kichura AL, Cory E, Bugbee WD, et al. Bone cysts after osteochondral allograft repair of cartilage defects in goats suggest abnormal interaction between subchondral bone and overlying synovial joint tissues. Bone. 2013;57:259–268. doi: 10.1016/j.bone.2013.08.011. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Pallante AL, Chen AC, Ball ST, et al. The in vivo performance of osteochondral allografts in the goat is diminished with extended storage and decreased cartilage cellularity. Am J Sports Med. 2012;40:1814–1823. doi: 10.1177/0363546512449321. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Whiteside RA, Jakob RP, Wyss UP, et al. Impact loading of articular cartilage during transplantation of osteochondral autograft. J Bone Joint Surg Br. 2005;87:1285–1291. doi: 10.1302/0301-620X.87B9.15710. [DOI] [PubMed] [Google Scholar]
  • 7.Pylawka TK, Wimmer M, Cole BJ, et al. Impaction affects cell viability in osteochondral tissues during transplantation. J Knee Surg. 2007;20:105–110. doi: 10.1055/s-0030-1248028. [DOI] [PubMed] [Google Scholar]
  • 8.Patil S, Butcher W, D'Lima DD, et al. Effect of osteochondral graft insertion forces on chondrocyte viability. Am J Sports Med. 2008;36:1726–1732. doi: 10.1177/0363546508316765. [DOI] [PubMed] [Google Scholar]
  • 9.Kock NB, van Susante JL, Wymenga AB, et al. Press-fit stability of an osteochondral autograft: Influence of different plug length and perfect depth alignment. Acta Orthop. 2006;77:422–428. doi: 10.1080/17453670610046352. [DOI] [PubMed] [Google Scholar]
  • 10.Repo RU, Finlay JB. Survival of articular cartilage after controlled impact. J Bone Joint Surg Am. 1977;59-A:1068–1076. [PubMed] [Google Scholar]
  • 11.Torzilli PA, Grigiene R, Borrelli J, Jr, et al. Effect of impact load on articular cartilage: cell metabolism and viability, and matrix water content. J Biomech Eng. 1999;121:433–441. doi: 10.1115/1.2835070. [DOI] [PubMed] [Google Scholar]
  • 12.Ewers BJ, Dvoracek-Driksna D, Orth MW, et al. The extent of matrix damage and chondrocyte death in mechanically traumatized articular cartilage explants depends on rate of loading. J Orthop Res. 2001;19:779–784. doi: 10.1016/S0736-0266(01)00006-7. [DOI] [PubMed] [Google Scholar]
  • 13.Milentijevic D, Torzilli PA. Influence of stress rate on water loss, matrix deformation and chondrocyte viability in impacted articular cartilage. J Biomech. 2005;38:493–502. doi: 10.1016/j.jbiomech.2004.04.016. [DOI] [PubMed] [Google Scholar]
  • 14.Torzilli PA, Deng XH, Ramcharan M. Effect of compressive strain on cell viability in statically loaded articular cartilage. Biomech Model Mechanobiol. 2006;5:123–132. doi: 10.1007/s10237-006-0030-5. [DOI] [PubMed] [Google Scholar]
  • 15.Quinn TM, Allen RG, Schalet BJ, et al. Matrix and cell injury due to sub-impact loading of adult bovine articular cartilage explants: effects of strain rate and peak stress. J Orthop Res. 2001;19:242–249. doi: 10.1016/S0736-0266(00)00025-5. [DOI] [PubMed] [Google Scholar]
  • 16.Szczodry M, Coyle CH, Kramer SJ, et al. Progressive chondrocyte death after impact injury indicates a need for chondroprotective therapy. Am J Sports Med. 2009;37:2318–2322. doi: 10.1177/0363546509348840. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.Finlay JB, Repo RU. Energy absorbing ability of articular cartilage during impact. Med Biol Eng Comput. 1979;17:397–403. doi: 10.1007/BF02443830. [DOI] [PubMed] [Google Scholar]
  • 18.Burgin LV, Aspden RM. Impact testing to determine the mechanical properties of articular cartilage in isolation and on bone. J Mater Sci Mater Med. 2008;19:703–711. doi: 10.1007/s10856-007-3187-2. [DOI] [PubMed] [Google Scholar]
  • 19.Ahsan T, Sah RL. Biomechanics of integrative cartilage repair. Osteoarthritis Cartilage. 1999;7:29–40. doi: 10.1053/joca.1998.0160. [DOI] [PubMed] [Google Scholar]
  • 20.Salem SA, Al-Hassani ST, Johnson W. Aspects of the mechanics of driving nails into wood. Int J Mech Sci. 1975;17:211–225. [Google Scholar]
  • 21.Pallante AL, Bae WC, Chen AC, et al. Chondrocyte viability is higher after prolonged storage at 37 degrees C than at 4 degrees C for osteochondral grafts. Am J Sports Med. 2009;37(Suppl 1):24S–32S. doi: 10.1177/0363546509351496. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22.Chang DG, Iverson EP, Schinagl RM, et al. Quantitation and localization of cartilage degeneration following the induction of osteoarthritis in the rabbit knee. Osteoarthritis Cartilage. 1997;5:357–372. doi: 10.1016/s1063-4584(97)80039-8. [DOI] [PubMed] [Google Scholar]
  • 23.Hurtig M, Buschmann MD, Fortier L, et al. Preclinical studies for cartilage repair: recommendations from the International Cartilage Repair Society. Cartilage. 2011;2:137–152. doi: 10.1177/1947603511401905. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Chu CR, Szczodry M, Bruno S. Animal models for cartilage regeneration and repair. Tissue Eng Part B Rev. 2010;16:105–115. doi: 10.1089/ten.teb.2009.0452. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25.Schinagl RM, Gurskis D, Chen AC, et al. Depth-dependent confined compression modulus of full-thickness bovine articular cartilage. J Orthop Res. 1997;15:499–506. doi: 10.1002/jor.1100150404. [DOI] [PubMed] [Google Scholar]
  • 26.Korhonen RK, Laasanen MS, Toyras J, et al. Comparison of the equilibrium response of articular cartilage in unconfined compression, confined compression and indentation. J Biomech. 2002;35:903–909. doi: 10.1016/s0021-9290(02)00052-0. [DOI] [PubMed] [Google Scholar]
  • 27.Armstrong CG, Lai WM, Mow VC. An analysis of the unconfined compression of articular cartilage. J Biomech Eng. 1984;106:165–173. doi: 10.1115/1.3138475. [DOI] [PubMed] [Google Scholar]
  • 28.Han E, Chen SS, Klisch SM, et al. Contribution of proteoglycan osmotic swelling pressure to the compressive properties of articular cartilage. Biophys J. 2011;101:916–924. doi: 10.1016/j.bpj.2011.07.006. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 29.Shepherd DET, Seedhom BB. The 'instantaneous' compressive modulus of human articular cartilage in joints of the lower limb. Rheumatology (Oxford) 1999;38:124–132. doi: 10.1093/rheumatology/38.2.124. [DOI] [PubMed] [Google Scholar]
  • 30.Rho JY, Ashman RB, Turner CH. Young's modulus of trabecular and cortical bone material: ultrasonic and microtensile measurements. J Biomech. 1993;26:111–119. doi: 10.1016/0021-9290(93)90042-d. [DOI] [PubMed] [Google Scholar]
  • 31.Choi K, Kuhn JL, Ciarelli MJ, et al. The elastic moduli of human subchondral, trabecular, and cortical bone tissue and the size-dependency of cortical bone modulus. J Biomech. 1990;23:1103–1113. doi: 10.1016/0021-9290(90)90003-l. [DOI] [PubMed] [Google Scholar]
  • 32.Bugbee W, Cavallo M, Giannini S. Osteochondral allograft transplantation in the knee. J Knee Surg. 2012;25:109–116. doi: 10.1055/s-0032-1313743. [DOI] [PubMed] [Google Scholar]
  • 33.Mall NA, Harris JD, Cole BJ. Clinical Evaluation and Preoperative Planning of Articular Cartilage Lesions of the Knee. J Am Acad Orthop Surg. 2015;23:633–640. doi: 10.5435/JAAOS-D-14-00241. [DOI] [PubMed] [Google Scholar]
  • 34.Su AW, Chen Y, Dong Y, et al. Energy density and shear are mechanical mediators of cartilage damage during impact. Trans Orthop Res Soc. 2014;39:1076. [Google Scholar]
  • 35.Claes L, Augat P, Suger G, et al. Influence of size and stability of the osteotomy gap on the success of fracture healing. Journal of Orthopaedic Research. 1997;15:577–584. doi: 10.1002/jor.1100150414. [DOI] [PubMed] [Google Scholar]
  • 36.Duchow J, Hess T, Kohn D. Primary stability of press-fit-implanted osteochondral grafts. Am J Sports Med. 2000;28:24–27. doi: 10.1177/03635465000280011601. [DOI] [PubMed] [Google Scholar]