Table 4.

Distribution of the discordant results between the 2016 guideline pressure estimates and invasive pressure measurements: breakdown by false negative, false positive, and indeterminate categories

Parameter Total number Number of false-negative* classifications Number of false-positive classifications Number of indeterminate classifications
E/A ratio   3   3 0 0
E/e′ ratio 18 10 6 2
LAVi 24   9 8 7
Peak TR velocity 10   4 6 0
Insufficient TR 13   7 1 5

TR, Tricuspid regurgitation.

See text for details.

*

Defined as normal filling pressure on echocardiography with elevated invasive pressure.

Defined as elevated filling pressure on echocardiography with normal invasive pressure.