Skip to main content
. 2018 Jan 8;8:87. doi: 10.1038/s41598-017-18035-0

Table 4.

Review of the literature about the effects of contrast agents on apparent diffusion coefficient (ADC) values in breast tumors.

Number of patients (N of lesions) Rubesova et al.16 Yuen et al.17 Janka R et al.18 Nguyen et al. (2016) Present study
5 (7; 2 benign, 5 malignant) 19 (19; 19 malignant) n/a (35; 10 benign, 25 malignant) 19 (19; 19 malignant of which 14 mass-like enhancing and 5 NMLE lesions) 27 (32; 7 benign, 25 malignant, all lesions mass-like enhancing lesions)
MRI field strength, vendor, manufacturer 1.5 T, Magnetom Symphony, Siemens 1.5 T, Gyroscan Intera Nova Dual, Philips 1.5 T, Magnetom Avanto, Siemens 3.0 T, Achieva Tx, Philips Achieva TX, Philips, Achieva Tx, Philips
b value combinations n/a ADC0,1000 ADC50,400,800 ADC0,100,800; ADC0,800; ADC100,800 ADC0,200,400,600,800; ADC400, 600,800; ADC0,200,400; ADC0,200,800; ADC0,400,800; ADC0,200; ADC0,800; ADC200,800
Contrast agent (dose mmol/kg) Gadodiamide (0.3) Gadopentetate dimeglumine (0.1) Gadobutrol (0.1) Gadoteridol (0.1) Gadoterate meglumine (0.2)
DCE-MRI acquisition time (minutes) 15 8 6 9 6
Median TR/TE (ms) 2600/110 1206/71 4100/98 5336/61 6982/95
Mean ± SD pre-contrast/post-contrast ADC values mm2/s (P) n/a (ns.) 1.35 ± 0.38/1.04 ± 0.34 (P = 0.01) Benign lesions: 1.99 ± 0.37/1.97 ± 0.30 (P = ns.). Malignant lesions: 0.90 ± 0.14/0.80 ± 0.14 (P < 0.01) ADC0,100,800: 1.10/1.10 (P = ns.)a ADC0,800: 1.14/1.09 (P = ns.)a A ADC100,800: 0.92/0.87 (P = ns.)a All lesions ADC0,200,400,600,800: 1.05 ± 0.35/1.03 ± 0.36 (P = 0.042). Other b value combinations: no significant differences in ADC values (P = ns.). Malignant lesions: ADC0,200,400,600,800: 0.93 ± 0.28/0.92 ± 0.28 (P = 0.042); ADC0,200,400: 0.92 ± 0.28/0.90 ± 0.27 (P = 0.040). Other b value combinations: no significant differences in ADC values (P = ns.). Benign lesions: No significant differences in ADC values (P = ns.).

N = number; n/a = not applicable information; ns. = not significant; TR = repetition time; TE = echo time; DCE-MRI = dynamic contrast enhanced magnetic resonance imaging.

aInstead of mean pre- and post-G-CA ADC values, the authors report median values.