Table 4.
SCI model | Biomaterial | Cell type | Outcome | References |
---|---|---|---|---|
Rat T11/T12 dorsal hemisection | 2 mm poly(D,L)-lactide biomatrix (Category II and IV) | OEC/ONF within and 1 mm rostrocaudal injections | Migration of cells up to but not within biomatrix, poor cell survival within biomatrix, increased axonal growth excluding CST, increased stride length and swing speed | Deumens et al., 2006a |
Rat T13 unilateral hemisection | 2 mm collagen-based multi-channel 3D matrices (Category II) | OEC | No improvement in CatWalk gait analysis or alleviation of allodynia | Deumens et al., 2013 |
Rat T9/T10 complete transection | 2 mm PLGA scaffolds (Category II) | OEC | Increased BBB score and crossing of inclined plane, increased axonal preservation, decreased astrogliosis | Wang et al., 2017 |