Table 2.
Results and uncertainties (k = 2) of B0430, t = 6.95 mm: μa, the absorption coefficient of the sample; the reduced scattering coefficient of the sample. The uncertainties on the INO results were estimated from measurements made on different samples at λ = 600 nm as presented in Ref. [3].
λ(nm) | μa × 10−3 (mm−1) | (mm−1) | ||
---|---|---|---|---|
| ||||
INO | NIST | INO | NIST | |
475 | 15.0 ± 1.7 | 14.6 ± 0.6 | 1.04 ± 0.07 | 1.09 ± 0.13 |
540 | 12.0 ± 1.5 | 12.5 ± 0.5 | 1.02 ± 0.07 | 1.09 ± 0.13 |
543 | 11.9 ± 1.3 | 12.5 ± 0.5 | 1.00 ± 0.07 | 1.08 ± 0.13 |
630 | 12.2 ± 1.4 | 11.5 ± 0.5 | 1.01 ± 0.07 | 1.06 ± 0.12 |
632 | 12.0 ± 1.4 | 11.5 ± 0.5 | 0.997 ± 0.070 | 1.05 ± 0.12 |
780 | 9.5 ± 1.1 | 9.5 ± 0.5 | 0.954 ± 0.067 | 1.00 ± 0.12 |
805 | 9.3 ± 1.1 | 9.2 ± 0.5 | 0.948 ± 0.066 | 0.98 ± 0.11 |
850 | 9.0 ± 1.0 | 8.9 ± 0.6 | 0.928 ± 0.065 | 0.97 ± 0.11 |