TABLE 7.
Data sets considered for the thermal conductivity of liquid tin at 0.1 MPa
| First author | Publ. year | Ref. | Purity (mass %) | Technique employeda | Uncertainty quoted (%) | No. of data | Temp. Range (K) | Form of datab |
|---|---|---|---|---|---|---|---|---|
| Previous reference correlation/values | ||||||||
| Mills | 1996 | [11] | 8 | 506–2073 | E | |||
| Touloukian | 1970 | [10] | 5–15 | 9 | 505–1300 | P | ||
|
| ||||||||
| Primary data | ||||||||
| Savchenko | 2011 | [50] | 99.996 | Laser flash (TD) | 2.5–3.5 | 21 | 513–1173 | D |
| Bilek | 2006 | [19] | 99.999 | Transient hot wire | 3 | 9 | 628–872 | P |
| Nagai | 2006 | [27] | 99.999 | Hot disk | - | 5 | 531–990 | D |
| Peralta-Martinez | 2006 | [18] | 99.99 | Transient hot wire | 2 | 8 | 534–731 | P |
| Sklyarchuk | 2005 | [35] | Guarded heat flow | 7 | 16 | 508–610 | D | |
| Hemminger | 1985 | [33] | 99.999 | Guarded heat flow | 5 | 17 | 512–769 | P |
| Otter | 1978 | [54] | 99.90 | Laser flash (TD) | 5 | 9 | 1261–2068 | D |
| Zinovyev | 1973 | [26] | - | Temperature wave (TD) | 10 | 7 | 506–592 | D |
| Osipenko | 1970 | [38] | - | Guarded heat flow | - | 8 | 538–898 | D |
| Dutchak | 1967 | [37] | - | Guarded heat flow | - | 5 | 526–775 | D |
| Kineke | 1967 | [32] | 99.00 | Guarded heat flow | 2 | 5 | 552–594 | D |
| Nikolsky | 1959 | [39] | - | Guarded heat flow | - | 29 | 579–834 | D |
| Brown | 1923 | [41] | - | Guarded heat flow | - | 3 | 537–621 | P |
| Konno | 1920 | [42] | - | Guarded heat flow | - | 3 | 565–772 | P |
|
| ||||||||
| Secondary data | ||||||||
| Yamasue | 2003 | [7] | 99.90 | Transient hot wire | 4 | 10 | 573–1473 | D |
| Shibata | 2002 | [55] | - | Laser flash (TD) | 30 | 2 | 623,829 | D |
| Banchila | 1973 | [66] | 99.995 | Temperature wave (TD) | 6 | 14 | 1153–1970 | D |
| Filippov | 1973 | [63] | - | Temperature wave (TD) | - | 10 | 507–1609 | D |
| Yurchak | 1965 | [64] | - | Temperature wave (TD) | 6–8 | 22 | 868–1226 | D |
| Pashaev | 1961 | [44] | 99.94 | Guarded heat flow | 5 | 5 | 513–608 | D |
| Bidwell | 1940 | [47] | - | Guarded heat flow | - | 2 | 505–745 | D |
TD = thermal diffusivity measurement
D = diagram, E = equation, P = table data