Skip to main content
. 2018 Jan 18;8:1103. doi: 10.1038/s41598-018-19429-4

Table 1.

Ellman’s tests confirmed the successful reduction of analysed PDIs. Upon DTT treatment and buffer exchanges, the percentage of reduced cysteine residues was tested by Ellman’s test. The concentrations of detected free disulfide groups were taken into the relation to the calculated concentration, which was taken from the protein concentration (measured by the absorption at 280 nm) multiplied by the numbers of cysteine residues in the individual PDIs. These concentrations were set to 100% of reduced cysteine residues. PDIA6 was tested in two experimental serials, ones together with PDIA1 and PDIA3, and ones with the indicated TRAP mutants. All tests were performed at least three times independently.

mean value mean value mean value
PDIA1 90.4 ± 11.8 PDIA6 96.5 ± 25.3 PDIA6_C55SC58S 90.5 ± 21.7
PDIA3 77.4 ± 30.4 PDIA6_C58S 115.8 ± 30.4 PDIA6_2 TRAP 102.4 ± 32.2
PDIA6 100.3 ± 4.0 PDIA6_C193S 115.2 ± 15.5 PDIA6_inverse TRAP 126.1 ± 40.3