Skip to main content
. 2018 Jan 18;8:1103. doi: 10.1038/s41598-018-19429-4

Table 2.

Dissociation constants (KD) of the PDI-MPD interaction with 68% confidence interval (CI) obtained by fitting the data from at least 3 independent MST analyses each with sixteen dilutions (1:2 dilution series) of the respective PDI at 25 °C. KD’s were calculated from the concentration-dependent ligand induced fluorescence intensity changes according to Eq. 1. Additional parameters resulting from the fit: Response amplitude of the fluorescence intensity shift between bound and unbound state, standard error (SE) of regression, reduced χ² and signal to noise.

Analyte Ligand KD ± 68% CI [nM] Response Amplitude [counts] n SE of Regression Reduced χ² Signal to Noise
PDIA1 opMPD 158 ± 34 298.9 3 19.75 0.45 16.25
clMPD 211 ± 67 210.4 5* 20.17 2.05 11.21
PDIA3 opMPD 90 ± 27 331.5 3 30.26 2.24 11.77
clMPD 55 ± 22 208.2 3 25.08 1.30 8.92
PDIA6 opMPD 93 ± 23 348.6 3 26.50 0.86 14.13
clMPD 61 ± 14 276.9 3 19.41 1.30 15.32
PDIA6 C58S opMPD 141 ± 38 411.6 3 34.58 3.73 12.79
clMPD 113 ± 31 198.2 3 16.87 0.69 12.62
PDIA6 C193S opMPD 142 ± 30 400.5 3 26.11 4.74 16.48
clMPD 91 ± 55 155.4 3 28.86 2.47 5.78
PDIA6 C58S C193S opMPD 192 ± 40 406.4 3 25.50 3.87 17.12
clMPD 151 ± 40 148.2 3 11.96 0.26 13.31
PDIA6 C55S C58S opMPD 138 ± 27 447.3 3 26.57 22.13 18.09
clMPD 191 ± 88 171.5 3 24.15 1.15 7.63
PDIA6 C55S C190S opMPD 115 ± 20 314.3 3 16.59 8.73 20.35
clMPD 116 ± 42 178.2 3 19.79 0.74 9.67

*Replicates increased to 5 due to variations at low concentration.