Skip to main content
. 2017 Nov 27;15(2):1203–1210. doi: 10.3892/etm.2017.5574

Table II.

Orthogonal test design.

Factor

Run no. A B C D Yield, %
1 1 1 1 1 3.46
2 1 2 2 2 3.96
3 1 3 3 3 4.48
4 2 1 2 3 4.81
5 2 2 3 1 5.03
6 2 3 1 2 4.82
7 3 1 3 2 4.32
8 3 2 1 3 3.64
9 3 3 2 1 3.86
K
  1 3.97 4.20 3.97 4.12
  2 4.89 4.21 4.21 4.37
  3 3.94 4.39 4.61 4.31
R 0.95 0.19 0.64 0.25

Data are presented as the mean. 1, 2 and 3 represent the factor levels 1, 2 and 3, respectively (30, 35 and 40 min duration; 65, 70 and 75% ethanol concentration, 70, 75 and 80°C temperature and 20:1, 25:1 and 30:1 liquid-to-solid ratio'. A, duration of ultrasonic treatment; B, ethanol concentration; C, temperature; D, liquid-to-solid ratio; K, the mean of the corresponding levels of flavonoids yield at each factor; R, the difference between the maximum and minimum values of K under each factor.