Skip to main content
. 2017 Jun 12;11(1):21–32. doi: 10.1016/j.optom.2017.04.001

Table 3.

Observed mean ± SD of subjective variables for the three study lenses.

Subjective variables (on a 1–10 scale, higher the better) EDOF AOMF AOP
Distance vision clarity Day 7.8 ± 1.7 7.9 ± 1.8 7.1 ± 2.2
Night 7.5 ± 1.8 7.5 ± 1.7 7.0 ± 2.0
Intermediate vision clarity Day 7.9 ± 1.6 7.5 ± 1.7 6.9 ± 1.6
Night 7.6 ± 1.7 7.2 ± 1.8 6.7 ± 1.5
Near vision clarity Day 7.4 ± 1.8 6.6 ± 2.0 6.0 ± 1.9
Night 7.1 ± 1.9 6.3 ± 2.2 5.7 ± 1.9
Distance lack of ghosting Day 8.2 ± 2.0 8.3 ± 2.2 7.5 ± 2.6
Night 7.9 ± 2.2 7.9 ± 2.2 7.4 ± 2.6
Intermediate lack of ghosting Day 8.5 ± 1.7 8.1 ± 2.0 7.5 ± 2.0
Night 8.3 ± 1.6 7.9 ± 2.1 7.6 ± 1.9
Near lack of ghosting Day 8.2 ± 1.9 7.6 ± 2.2 7.1 ± 2.3
Night 8.1 ± 1.8 7.3 ± 2.3 7.1 ± 2.2
Vision stability Day 8.1 ± 1.4 7.9 ± 1.7 7.3 ± 2.0
Night 8.2 ± 1.2 7.8 ± 1.7 7.4 ± 1.7
Driving vision Day 8.0 ± 1.6 8.0 ± 1.5 7.2 ± 2.1
Night 7.5 ± 1.7 7.4 ± 1.4 6.8 ± 2.0
Lack of bothersome haloes at night 8.9 ± 1.5 8.3 ± 2.0 8.3 ± 2.2
Overall vision satisfaction 7.6 ± 1.8 6.7 ± 2.1 5.7 ± 2.6
Ocular comfort 8.5 ± 1.3 7.6 ± 1.9 8.0 ± 1.6

EDOF = extended depth of focus.

AOMF = AIR OPTIX Aqua multifocal.

AOP = ACUVUE OASYS for Presbyopia.