Skip to main content
. 2018 Jan 26;8:1711. doi: 10.1038/s41598-018-19440-9

Figure 14.

Figure 14

Sensitivity to lumen constrictions and angulation between XRA views. (a) Preview of the total 19 XRA views considered for reconstruction, and the numbers above the projections indicate primary angle (PA) right anterior oblique (RAO)/left anterior oblique (LAO). (b) Front and (c) Top view of the ground-truth surface (phantom). (df) Surface obtained by polygonal approximation vs. ground truth. (gi) Surface obtained by circle fitting vs. ground truth. (jl) Surface obtained by ellipse fitting vs. ground truth. (mp) Comparison of the cross-section assessment approaches for reconstruction of the concave (plaque) region. (q) Influence of angle between the X-ray angiography (XRA) views on the accuracy.