Skip to main content
. 2017 Dec 10;32(1):64–71. doi: 10.1111/jvim.14884

Table 3.

Intra‐ and interobserver repeatability for RV function indices in 12 dogs with MMVD

Intra‐observer repeatability Bland–Altman CV (%) Interobserver repeatability Bland–Altman CV (%)
Bias LOA* Bias LOA*
TAPSE (mm) 0.0 −0.2, 0.2 0.5 TAPSE (mm) −0.3 −1.5, 1.0 3.6
RV S' (cm/s) −0.2 −1.4, 0.9 3.6 RV S' (cm/s) 0.4 −1.7, 2.5 6.4
RV FAC (%) 3.0 −9.0, 15.0 8.4 RV FAC (%) 4.7 −23.5, 32.9 17.3
RV StL (%) 0.6 −8.2, 9.3 11.4 RV StL (%) 10.1 −30.0, 50.2 12.3
RV StRL (s−1) 0.0 −1.5, 1.6 17.9 RV StRL (s−1) 3.8 −2.9, 10.4 20.1
RV StG (%) 0.0 −4.5, 4.6 6.5 RV StG (%) −0.2 −6.0, 5.7 8.4
RV StRG (s−1) 0.1 −0.6, 0.8 9.1 RV StRG (s−1) 0.5 −1.0, 2.0 16.9

TAPSE, tricuspid annular plane systolic excursion; RV S', systolic myocardial velocity of the lateral tricuspid annulus; RV FAC, fractional area change in the right ventricular inlet; RV StL, longitudinal strain of the right ventricular free wall; RV StRL, longitudinal strain rate of the right ventricular free wall; RV StG, global longitudinal strain of the right ventricle; RV StRG, global longitudinal strain rate of the right ventricle.

*95% limits of agreement, CV, coefficient of variation.