Efficiency of 68Ga-PSMA PET/CT in patients with biochemical relapse (low rising PSA) – status October 2017

AUTHORS DESIGN TOTAL number PSA 0.0–0.1 PSA 0.1–0.2 PSA 0.2–0.3 PSA 0.3–0.5 PSA 0.5–0.8 PSA 0.8 < 1 PSA 1–2 PSA > 2 PET/CT SCANNER IMAGE AQUISITION
van Leeuwen et al. [53] Prosp n = 300 n = 13 n = 22 n = 17 n = 11 n = 7 Ingenuity TOF, Philips 45 min
8% 23% 58% 36% 57%
Afshar-Oromieh et al. [54]
Afshar-Oromieh et al. [55]
Retrosp
Retrosp
n = 319
(83%)*
n = 801/
1007
(79.5%)*
n = 8/17 n = 5/10 n = 14/24 n = 28/39 Biograph, Siemens 60 min
47.10% 50% 58.30% 71.80%
n = 32/69 n = 50/108 n = 87/119 n = 132/166 n = 467/509
46% 46% 73% 80% 91.75%
Eiber et al. [56]
Maurer et al. [75]
Einspieler et al. [57]
Retrosp
Retrosp
Retrosp
n = 248
(90%)*
n = 332
107/118
(90.7%)*
n = 11/19 n = 24/33 n = 67/72 n = 120/124 Biograph, Siemens 60 min
57.89% 72.73% 93.06% 96.77%
n = 13/23 n = 25/35 n = 67/71 n = 122/127
56.5% 71.4% 94.4% 96.1%
n = 107/118
(90.7%)
Verburg et al. [51] Retrosp n = 155
(89%)*
n = 12/27 n = 15/19 n = 97/109 GEMINI TF16, Philips 60 min
44% 79% 89%
Morigi et al. [85] Prosp n = 37/38 n = 8/16 n = 10/14 n = 7/8 Ingenuity TOF, Philips 45 min
50% 71% 88%
Kabasakal [58] Retrosp n = 29/50
(58%)*
n = 4 n = 11 n = 14 Biograph, Siemens 45–60 min
33% 50% 87.5%
Ceci et al. [50] Retrosp n = 52/70
(74.2%)*
n = 21 n = 49 Discovery, GE 8 min, 60 min, (120 min)
47.60% 85.70%
Sachpekidis et al. [59] Retrosp n = 22/31
(71%)*
n = 4/11 n = 15/20 Biograph, Siemens Dynamic for 60 min (pelvis), WB at 80–90 min p.i.
36.36% 75%
Albisinni et al. [62] Retrosp n = 98/131
(75%)
45% 83% GE Discovery 690 60 min

*Overall detection rate