Skip to main content
. 2018 Feb 1;13(2):e0191802. doi: 10.1371/journal.pone.0191802

Table 1. Summary of results.

Tool Change in body length (tool expressed in BWM) [%] τrelax [s] Light sensitivity Repeatabilityof stimulation off-ATR excitability Advantages of the most significant opsins screened
DEPOLARIZERS
ChR2(H134R) -14.9 1.1 - ++
ChR2(C128S) -14.6 181.7 ++ - -
ChR2(L132C) CatCh -13.5 0.7 o
ChR2(T159C) -6.4 0.3
ChR2(C128S;H134R) -14.6 841.3 ++ + ++
ChR2(H134R;D156C) -14.3 527.8 ++++ ++
ChR2(H134R;T159C) -14.7 0.6
ChR2(C128S;L132C;H134R) -10.7 1253.9 +++
ChR2(L132C;H134R;T159C) -16.3 2.3 +++
ChR2(C128S;L132C;H134R;D156A;T159C) Quint -12.8 45370.1 +++ + very slow closing kinetics high operational light sensitivity good off-ATR excitability
HYPERPOLARIZERS
ACR1 +6.1 0.57 +++++ + high photocurrents high operational light sensitivity red-shifted action spectrum
ACR2 +4.8 0.14 +++++ + high photocurrents high operational light sensitivity high temporal precision
ACR1(C102A) +3.4 26.04 +++++
ZipACR PsuACR_973 +4.5 0.15 + +
NpHR +3.5 0.16 - +
Mac +3.9 0.09 +
Arch +4.2 0.24 +