. 2017 Dec 23;19(1):25. doi: 10.3390/ijms19010025

Table 3.

Inter-day and intra-day assay precision (% RSD) and accuracy (% Bias) values for the HPLC–UV method for the quantification of 5-FU and 5-FDHU in rat plasma.

Nominal Con. (µg/mL) Intra-Day (n = 6) Inter-Day (n = 6)
Observed Con. (µg/mL) Accuracy Bias (%) Precision RSD (%) Observed Con. (µg/mL) Accuracy Bias (%) Precision RSD (%)
5-FU
0.1 0.111 ± 0.01 10.6 6.58 0.102 ± 0.01 2.02 11.5
0.5 0.528 ± 0.04 5.69 1.03 0.487 ± 0.04 −2.69 7.35
1 0.971 ± 0.03 −2.92 2.70 0.966 ± 0.03 −3.45 3.32
5 5.018 ± 0.05 0.37 1.08 4.965 ± 0.12 −0.70 2.43
10 10.02 ± 0.12 0.21 1.16 10.04 ± 0.12 0.40 1.17
50 50.15 ± 0.13 0.30 0.26 49.98 ± 0.02 −0.04 0.05
5-FDHU
0.1 0.101 ± 0.01 0.60 8.88 0.092 ± 0.01 −7.98 5.70
0.5 0.489 ± 0.04 −2.23 7.43 0.503 ± 0.01 0.51 1.74
1 1.044 ± 0.04 4.41 3.44 1.025 ± 0.04 2.45 3.61
5 4.766 ± 0.25 −4.68 5.20 4.867 ± 0.17 −2.65 3.50
10 10.26 ± 0.31 2.61 3.03 10.11 ± 0.19 1.05 1.84
50 50.16 ± 0.30 0.31 0.59 49.99 ± 0.04 −0.02 0.09

Data are expressed as the means ± SD. Precision (%RSD) = SD/Cobs × 100. Accuracy (%Bias) = (Cobservation − Cnominal)/Cnominal × 100.