Skip to main content
. 2016 Aug 4;24(1):24–42. doi: 10.1177/1460458216656471

Table 6.

Recall, specificity and precision for optimized GTB-Stem compared with the results found in the “Related work” section.

Recall Specificity Precision
GTB-Stem optimized 93.7 64.1 79.7
[7] ANN Internal 96.64 85.96
[7] LR external 82.76 80.90
[10] SVM 92.6 43.73
[11] SVM 92.0 72.0
[11] NB 87 74.0
[13] FLD S2 82.56 43.54

GTB: gradient tree boosting; ANN: artificial neural network; LR: linear regression; SVM: support vector machine; NB: Naïve Bayes classifiers; FLD: Fisher’s linear discriminant.

Note that the evaluation methods and datasets are not the same.