Skip to main content
. 2017 Dec 31;2017:2692604. doi: 10.1155/2017/2692604

Table 1.

Sensitivity, specificity, positive predictive value, and negative predictive value of BerEP4 in detecting BCC with SCC as control.

Studies BCC + SCC + (control)
Karahan, et al. [16] 20/20 0/20
Fan, et al. [28] 51/51 -
Krahl & Sellheyer [29] 28/28 -
Ishida, et al. [30] 20/20 -
Filho, et al. [31] 20/20 -
Mashhood, et al. [32] 29/29 0/11
Tan & Sunjaya [9] 23/23 -
Kirzhner & Jakobiec [33] 13/13 -
Dasgeb, et al. [24] 24/24 1/11 (weak positive)
Patil, et al. [12] 9/9 -
Sellheyer, et al. [34] 17/17 0/75
Ansai, et al. [35] 30/31 -
BerEP4 positive 284 1
Ber EP4 negative 1 116

Total 285 117

Sensitivity 284/285 × 100 = 99.6%
Specificity 116/117 × 100 = 99.2%
Positive predictive value 284/285 × 100 = 99.6%
Negative predictive value 116/117 × 100 = 99.1%