Table 1.

Scoring system of amplitude integrated electroencephalography (aEEG)

Score Curve variability SWC Lower boundary values Narrow-band width and lower boundary voltage
0 No variation curve None Seriously inhibited (< 3 μV) Amplitude suppression: low amplitude (≤15 μV) and low voltage (5 μV)
1 Some curve, no sinusoidal ariation Starting occurrence period Some inhibition (3~ 5 μV) Immaturity amplitude: high amplitude (> 20 μV) or medium amplitude (15~ 20 μV) and low voltage (5 μV)
2 Sinusoidal ariation No clear No inhibition (> 5 μV) Immaturity amplitude: high amplitude (> 20 μV) and high voltage (> 5 μV)
3 Clear period, but suspension Gradually mature amplitude: medium amplitude (15~ 20 μV) and high voltage (> 5 μV)
4 Clear period, no suspension Mature amplitude: low amplitude (< 15 μV) and high voltage (> 5 μV)
5 Rule and mature period