Skip to main content
. 2017 Nov 6;89(1):29–39. doi: 10.1080/17453674.2017.1398011

Summary of studies comparing ultrasound and MARS-MRI for detecting adverse reactions to metal debris and pseudotumors

Positive Negative
Sensitivity Specificity predictive predictive
Study (participants) (%) (%) value (%) value (%)
Garbuz et al. 2014 (40 hips)
 Ultrasound vs. MARS-MRIa 100 96 92 100
 MARS-MRI vs. ultrasounda 92 100 100 96
Siddiqui et al. 2014 (19 hips)
 Ultrasound vs. MARS-MRa 69 83 90 56
Nishii et al. 2014 (64 hips)
 Ultrasound vs. MARS-MRIa 74 92 NS NS
Muraoka et al. 2015 (83 hips)
 Ultrasound vs. MARS-MRIa 72 88 65 91
Kwon et al. 2016a (42 hips)
 Initial: Ultrasound vs. MARS-MRIa 81 92 86 88
 Repeat: Ultrasound vs. MARS-MRIa 86 88 75 94
Matharu et al. 2016e (40 hips)
 Ultrasound vs. intraoperativea 91 43 88 50
 MARS-MRI vs. intraoperativea 94 57 91 67
 Combined imaging (ultrasound & MARS-MRI) vs. intraoperativea 100 57 92 100

NS = not stated.

a

Gold reference standard for diagnostic test characteristics