Skip to main content
. Author manuscript; available in PMC: 2019 Feb 1.
Published in final edited form as: J Card Fail. 2017 Sep 12;24(2):65–73. doi: 10.1016/j.cardfail.2017.09.004

Table 2.

Cardiorespiratory and perceptual responses to steady-state exercise.

Power output (W)
Trial 20 40 60
VO2 (L/min) Placebo 0.81 ± 0.09 1.00 ± 0.09 1.26 ± 0.12
Nitrate 0.87 ± 0.10 1.08 ± 0.11 1.34 ± 0.13
VO2 (mL.min-1.kg-1) Placebo 7.8 ± 0.4 9.8 ± 0.7 12.3 ± 1.0
Nitrate 8.4 ± 0.5 10.5 ± 0.7 13.1 ± 1.0
% of VO2peak Placebo 38.5 ± 3.9 48.1 ± 5.0 60.6 ± 6.6
Nitrate 38.0 ± 3.2 47.5 ± 4.0 59.1 ± 4.9
Ve (L/min) Placebo 22.5 ± 2.7 26.8 ± 2.9 33.9 ± 4.1
Nitrate 24.1 ± 3.6 29.5 ± 4.6 36.1 ± 5.3
Ve/VO2 (L/L) Placebo 27.5 ± 1.0 26.5 ± 1.0 26.6 ± 1.3
Nitrate 27.2 ± 1.5 26.6 ± 1.7 26.4 ± 1.7
Ve/VCO2 (L/L) Placebo 33.9 ± 1.2 31.8 ± 1.3 30.6 ± 1.2
Nitrate 33.5 ± 1.7 32.2 ± 1.6 30.9 ± 1.6
Respiratory exchange ratio Placebo 0.81 ± 0.01 0.83 ± 0.01 0.87 ± 0.02
Nitrate 0.81 ± 0.02 0.82 ± 0.02 0.85 ± 0.02
Gross efficiency (%) Placebo 7.6 ± 0.8 12.1 ± 1.2 14.4 ± 1.4
Nitrate 7.2 ± 0.6 11.3 ± 0.9 13.6 ± 1.1
Heart rate (beats/min) Placebo 85 ± 3 98 ± 7 103 ± 5
Nitrate 96 ± 5 101 ± 4 107 ± 9
Systolic blood pressure (mmHg) Placebo 136 ± 7 141 ± 7 143 ± 8
Nitrate 132 ± 9 137 ± 9 136 ± 8
Diastolic blood pressure (mmHg) Placebo 76 ± 5 75 ± 5 76 ± 5
Nitrate 84 ± 5 81 ± 4 78 ± 5
Perceived exertion (units) Placebo 8 ± 1 9 ± 1 10 ± 1
Nitrate 8 ± 1 10 ± 1 12 ± 1

Values are mean±S.E. for n=8. VO2, oxygen uptake. Ve, ventilation. VCO2, carbon dioxide production.