Table 4.

Scan‐Rescan Comparison of 2D Stroke Volume (SV) and Flow Through the Mitral (MV) and Aortic Valve (AV)

Scan 1 Scan 2 Difference (mL)a Pearson correlation coefficient Intraclass correlation coefficient Coefficient of variation (%)
Mean ± SD (min ‐max) Mean ± SD (min ‐max) Mean ± SD (min‐max) ICC (95% C.I.)
2D planimetry
SV (mL) 103.5 ± 22.8 (77.0‐135) 104.3 ± 22.1 (74.4‐131.9) 0.8 ± 7.0 (‐9.2‐12.9) 0.95b 0.98 (0.91‐0.99)b 7
Retrospective valve tracking
MV flow (mL) 95.4 ± 17.0 (71.4‐121.2) 97.6 ± 24.0 (62.3‐135.0) 2.2 ± 11.3 (‐16.7‐17.6) 0.90b 0.92 (0.70‐0.98)b 12
AV flow (mL) 92.7 ± 15.5 (68.4‐112.9) 95.3 ± 20.9 (66.0‐95.3) 2.6 ± 11.7 (‐18.4‐20.7) 0.83c 0.89 (0.58‐0.97)c 12
Backward and forward particle tracing for LV in‐ and outflow
MV flow (Backward only) (mL) 91.7 ± 23.6 (57.5‐133.1) 94.1 ± 20.0 (63.3‐121.8) 2.4 ± 10.7 (‐11.3‐18.2) 0.89c 0.94 (0.77‐0.99)b 11
AV flow (Forward only) (mL) 91.6 ± 14.0 (71.5‐112.1) 88.1 ± 13.6 (68.2‐105.2) ‐3.5 ± 8.2 (‐18.7‐9.5) 0.83c 0.90 (0.61‐0.97)c 9
Multicomponent particle tracing for LV in‐ and outflow
MV flow (Direct flow + retained inflow) (mL) 82.9 ± 20.1 (56.0‐113.5) 83.7 ± 19.2 (57.1‐109.6) 0.8 ± 13.6 (‐12.7‐26.5) 0.76c 0.88 (0.48‐0.97)c 16
AV flow (Direct flow + delayed ejection flow) (mL) 89.9 ± 13.8 (71.2‐109.5) 84.1 ± 14.5 (59.2‐103.3) ‐5.8 ± 10.7 (‐22.7‐13.3) 0.72c 0.81 (0.29‐0.95)c 12
a

Differences were calculated with the paired samples t‐test.

b

P < 0.001.

c

P < 0.05.

AV = aortic valve, MV = mitral valve, SV = stroke volume.