Skip to main content
. 2016 Sep 16;20(1):10–17. doi: 10.1080/15685551.2016.1231031

Table 1. Thermo-mechanical and thermal-stability results.

Sample Tg a (°C) Weight loss (°C)
Tmax e Residual mass (600 °C) (%)
Td 5% b Td 50% c Td 90% d
ECO 45 162 355 423 368 1.2
ECO_POSS1Ep 51 272 369 422 382 1.7
ECO_POSS8Ep 64 299 384 446 391 3.0
a

T g – the maximum of tan δ plots was considered for the glass transition temperature (T g) determination.

b

T d 5% – temperature at which the mass loss of the sample is 5%.

c

T d 50% – temperature at which the mass loss of the sample is 50%.

d

T d 90% – temperature at which the mass loss of the sample is 90%.

e

T max – temperature at which the weight loss is maximum.