Master plot for effective thermal effusivity. Master plot of effective thermal effusivity for phase change materials measured in the literature and this work (references in brackets6, 3437). Results are confined to isotropic and ambient phase change materials (transition temperature T* occurring between 20 and 40 °C), for which volume-specific latent heat and thermal conductivity are directly or indirectly reported. The four data points enclosed in the ellipse refer to this work for graphene-modified and pristine Ni and Cu foams infused with OD