TABLE 4.
Standard Group | EndoTool Group | RR (%) | P | |
---|---|---|---|---|
Rate of hypoglycemia while on insulin drip (mean [range]) | 0.036 (0–1) | 0.007 (0–0.2) | –80.6 | 0.17 |
Rate of hyperglycemia while on insulin drip (mean [range]) | 0.358 (0–1) | 0.283 (0–1) | –20.9 | 0.25 |
Time to achieve target blood glucose (hours; mean [range]) | 2.78 (0–16) | 3.67 (0–16) | +32.0 | 0.27 |
Values within target blood glucose range (mean [range]) | 0.452 (0–1) | 0.473 (0–1) | +4.6 | 0.71 |
Rate of blood glucose monitoring/hour (mean [range]) | 1.45 (0.60–1.95) | 1.18 (0.91–2.00) | –18.6 | * |
Statistical analysis of P value not performed.