Skip to main content
. 2018 Feb 19;8:3300. doi: 10.1038/s41598-018-21599-0

Table 4.

Arterial function of patients with multiple sclerosis and control subjects. Data are expressed as mean ± SD.

Parameter Multiple sclerosis Control Subjects P-value
IMT (mm) 0.5 ± 0.1 0.6 ± 0.1 NS
Ep (kPa) 70 ± 34 61 ± 30 NS
β index 5.5 ± 2.5 5.3 ± 2.1 NS
AiX (%) 15.8 ± 7.24 3.9 ± 3 NS
AC (cm2/mmHg) 1.1 ± 0.3 1 ± 0.4 NS
PWV CF (m/s) 7.32 ± 1.47 6.34 ± 1.68 NS
FMD (%) 15.29 ± 9.44 16.72 ± 11.46 NS

IMT = intima media thickness; Ep = Peterson’s elastic modulus; AiX = augmentation index; AC = arterial compliance; PWV CF = pulse wave velocity carotid-femoral; FMD = flow mediated dilation.