Skip to main content
. Author manuscript; available in PMC: 2019 Mar 1.
Published in final edited form as: Ear Hear. 2018 Mar-Apr;39(2):293–304. doi: 10.1097/AUD.0000000000000486

Table 1. General Prototype Listening Situations (gPLS).

Subgroup Numbering Cluster size Speech level (dBA) Noise level (dBA) SNR (dB) Visual cues Talker location Noise location
Quiet 1 115 (16%) 63.9 50.5 13.4 Always Front N/A (quiet)
2 96 (13%) 61.5 50.6 10.9 Sometimes Side N/A (quiet)
3 45 (6%) 60.4 50.4 10.0 Sometimes Front N/A (quiet)
4 37 (5%) 65.4 51.0 14.4 Always Side N/A (quiet)
5 20 (3%) 62.6 50.7 11.9 Sometimes Back N/A (quiet)

Diffuse Noise 6 93 (13%) 68.5 59.9 8.6 Always Front All around
7 87 (12%) 67.3 60.9 6.4 Sometimes Side All around
8 74 (10%) 68.8 64.0 4.8 Sometimes Front All around
9 53 (7%) 68.7 59.4 9.2 Always Side All around
10 20 (3%) 67.4 60.6 6.7 Sometimes Back All around

Non-Diffuse Noise 11 42 (6%) 64.4 54.9 9.5 Always Front Front
12 36 (5%) 69.5 61.9 7.6 Sometimes Side Side