Skip to main content
. Author manuscript; available in PMC: 2018 Mar 1.
Published in final edited form as: Clin Lung Cancer. 2017 Oct 13;19(2):148–156.e3. doi: 10.1016/j.cllc.2017.10.002

Table 2.

The performance of top semantic features, feature combinations, and lung-RADS in predicting nodule malignancy at each screening round (a: baseline scan, b: first follow-up scan, c: second follow-up scan)

2a Baseline scan (T0)
Features Semantics Lung-RADS Combined
Sensitivity/
Specificity
E[AUC]*
[CI]
Testing
AUC
Sensitivity/
Specificity
E[AUC]
CI
AUC
[CI]
Border definition 0.579 / 0.834 0.719 [0.582,0.825] 0.787 0.399 – 0.466 / 0.750 – 0.794 0.600 [0.404,0.719] 0.743 [0.601,0.878]
Contour 0.372 / 0.915 0.689 [0.484,0.864] 0.835 0.685 [0.471,0.851]
Border definitionFocal fibrosis 0.571 / 0.839 0.692 [0.542,0.825] 0.789 0.732 [0.587,0.881]
Border definition solidity Vessel attachment 0.549 / 0.858 0.731 [0.582,0.896] 0.782 0.704 [0.512,0.913]
Short axial diameter Contour Border definition solidity 0.525 / 0.888 0.741 [0.574,0.855] 0.927 0.732 [0.555,0.852]
2b First follow-up scan (T1)
Features Semantics Lung-RADS Combined
Sensitivity/
Specificity
E[AUC]*
[CI]
Testing§
AUC
AUC E[AUC]
CI
AUC
[CI]
Contour 0.689 / 0.898 0.823 [0.722,0.944] 0.835 0.537 – 0.621/0.949 – 0.970 0.760 [0.614,0.919] 0.875 [0.775,0.944]
Border definition 0.695 / 0.815 0.741 [0.595,0.864] 0.787 0.846 [0.752,0.983]
Location Contour 0.678 / 0.905 0.833 [0.739,0.925] 0.820 0.886 [0.793,0.969]
Contour Vessel attachment Focal emphysema 0.687 / 0.901 0.882 [0.776,0.966] 0.843 0.835 [0.525,0.967]
Location Contour solidity Focal fibrosis 0.665 / 0.907 0.897 [0.807,0.974] 0.825 0.897 [0.807,0.974]
2c Second follow-up scan (T2)
Features Semantics Lung-RADS Combined
Sensitivity/
Specificity
E[AUC]*
[CI]
Testing
AUC
Sensitivity/
Specificity
E[AUC]
CI
AUC
[CI]
Contour 0.829 / 0.871 0.876 [0.742,0.97] 0.835 0.767 – 0.847/0.953 – 0.973 0.867 [0.760,0.973] 0.958 [0.877,0.993]
Border definition 0.729 / 0.806 0.802 [0.642,0.924] 0.787 0.938 [0.845,0.992]
Location Contour 0.816 / 0.881 0.897 [0.757,0.979] 0.820 0.962 [0.883,0.991]
Contour Vessel attachment Focal emphysema 0.823 / 0.881 0.903 [0.786,0.974] 0.843 0.965 [0.894,0.994]
Location Short axial diameter Contour Focal emphysema 0.744 / 0.943 0.947 [0.881,0.987] 0.923 0.968 [0.913,0.995]

It indicates the combination of lung-RADS with semantic features.

§

there are only 2 screening rounds for the testing cohort, so we used the same dataset for baseline and the first follow-up scan.

*

E[AUC] means average area under the receiver-operating characteristic curve, CI stands for confidence interval.