Table 4. Comparison of total retinal thickness of the macular region and of the temporal retina between sickle cell disease eyes and control subjects.
ETDRS grid quadrant | Thickness (μm) | |||
---|---|---|---|---|
SCD subjects (n = 59) | Controls (n = 59) | p-value | ||
Macula | Fovea | 267.2 | 282.7 | <0.0001 |
Inferior | 312.3 | 320.4 | 0.0014 | |
Nasal | 325.8 | 337.4 | <0.0001 | |
Superior | 316.6 | 328.9 | <0.0001 | |
Temporal | 298.7 | 312.0 | <0.0001 | |
Temporal Retina* | Inferior | 232.6 | 240.9 | 0.0017 |
Superior | 236.3 | 241.0 | 0.0114 | |
Temporal | 215.8 | 224.0 | 0.0006 |
SCD, sickle cell disease.
*Thickness data from the nasal quadrant of the temporally-centered grid were not collected because of overlapping with the temporal quadrant of the fovea-centered grid