Table 1.

Parameters for 3-T images

Sequence Spatial resolution (mm) TR (ms) TE (ms) FOV (mm) Averages Flip angle TA (min:s)
2D T2 TSE axial 0.6 × 0.6 × 3 4000 101 200 3 150 4:10
2D T2 TSE sagittal 0.6 × 0.6 × 3 4000 101 200 3 150 3:46
2D T2 TSE Coronal 0.6 × 0.6 × 3 4000 101 200 3 150 3:38
Total time 11:14
3D T2 SPACE 0.8 × 0.8 × 0.8 1800 179 320 2 100 3:45
Total time 3:35
DWI 1.6 × 1.6 × 3.6 3300 60 260 8 2:29
T1 TWIST DCE 1 × 1 × 3.6 3.85 1.42 260 1 2.5/10/20 5:02
Total time 7:31

2D two-dimensional, DWI diffusion weighted imaging, FOV field of view, SPACE Sampling Perfection with Application optimized Contrasts using different flip angle Evolution, TA time of acquisition, TE echo time, TR repetition time, TSE turbo spin echo, TWIST Time-resolved angiography With Interleaved Stochastic Trajectories; all sequences were acquired with GeneRalized Autocalibrating Partially Parallel Acquisition (GRAPPA) factor 2