Skip to main content
. 2018 Mar 1;265:56–64. doi: 10.1016/j.electacta.2018.01.118

Table 4.

Open circuit voltage, maximum power density and short circuit current density for the MFCs during overall polarization curves.

Catalyst Open circuit
Max. power
Short circuit current
voltage (V) density (μW cm−2) density (μA cm−2)
AC-0 0.64 ± 0.01 103 ± 4 992 ± 43
AC-2 0.67 ± 0.01 105 ± 1 932 ± 34
GNS-2 0.67 ± 0.01 150 ± 5 1172 ± 23
Fe-AAPyr-2 0.74 ± 0.02 218 ± 5 1355 ± 10
Fe-AAPyr-2-GNS-2 0.74 ± 0.01 235 ± 1 1500 ± 4