Skip to main content
. Author manuscript; available in PMC: 2018 Mar 12.
Published in final edited form as: Cochlear Implants Int. 2014 Oct 20;16(3):159–167. doi: 10.1179/1754762814Y.0000000101

Table 3.

Summary of regression analysis for variables predicting bimodal benefit (n = 14)

Variable +5 dB SNR
+10 dB SNR
Quiet
Beta pc Beta pc Beta pc
Consonant CI–HA −0.18 −0.52* −0.16 −0.48* −0.16 −0.56*
HA alone 0.03 0.05 0.11 0.16 −0.03 −0.07
R2 0.39 0.37 0.44
F(2, 11) 3.59* 3.08* 4.31*
Vowel CI–HA −0.36 −0.64* −0.38 −0.73** −0.23 −0.64*
HA alone 0.09 0.23 −0.01 −0.04 0.01 0.05
R2 0.62 0.69 0.63
F(2, 11) 8.94** 12.15** 9.36**
Sentence CI–HA −0.28 −0.64* −0.21 −0.54* −0.28 −0.66*
HA alone 0.01 0.45 0.05 −0.05 0.21 −0.62*
R2 0.58 0.43 0.44
F(2, 11) 7.54* 4.13* 4.21*

pc=partial correlation.

*

P< 0.50.

**

P< 0.01.