Skip to main content
. 2018 Feb 1;19(2):154–159. doi: 10.1002/acm2.12266

Table 2.

Median (range) of percentage PTV and GTV dose errors in Type‐A dose calculations comparing IMRT and DCA for the 20 patients. The bolded p values indicate statistically significant differences for the high‐dose region endpoints D5% and Dmax of both PTV and GTV, where IMRT resulted in significant lower dose errors than DCA (p < 0.05)

PTV Dmin PTV D95% PTV Dmean PTV D5% PTV Dmax
IMRT 17.6% (13.2–36.9%) 15.2% (12.1–32.7%) 9.1% (6.4–17.1%) 4.3% (1.2–8.9%) 2.9% (1.1–8.2%)
DCA 23.1% (14.5–34.2%) 16.1% (14.4–33.1%) 7.6% (6.2–17.9%) 5.1% (1.9–10.1%) 4.1% (1.8–8.5%)
p value 0.46 0.62 0.57 0.0002 0.003
GTV Dmin GTV D95 GTV D50 GTV D5 GTV Dmax
IMRT 12.2% (6.4–24.7%) 6.9% (3.8–14.8%) 6.1% (2.9–9.3%) 3.3% (2.1–6.9%) 2.9% (1.1–8.1%)
DCA 9.8% (2.3–16.8%) 7.0% (4.1–13.2%) 5.3% (3.1–8.7%) 4.0% (3.0–7.2%) 3.7% (1.2–8.5%)
p value 0.45 0.86 0.43 0.0013 0.008