Skip to main content
. 2018 Feb 1;19(2):154–159. doi: 10.1002/acm2.12266

Table 3.

Median (range) of percentage PTV and GTV dose errors in Type‐B dose calculations comparing IMRT vs DCA and VMAT vs DCA for the 20 patients

PTV Dmin PTV D95% PTV Dmean PTV D5% PTV Dmax
IMRT 3.8% (−0.8 to 17.9%) 2.4% (−1.9 to 11.3%) 1.1% (−2.8 to 5.1%) −2.3% (−5.8 to 0.9%) −2.7% (−5.2 to 1.0%)
VMAT 3.5% (−0.6 to 13.3%) 2.1% (−0.6 to 10.4%) 1.2% (−3.0 to 4.8%) −1.8% (−5.5 to 1.1%) −2.2% (−5.8 to 1.3%)
DCA 3.1% (−1.2 to 10.8%) 1.2% (−2.9 to 9.1%) 0.5% (−1.8 to 4.2%) −0.4% (−4.2 to 0.9%) −0.7% (−4.4 to 1.6%)
p value (IMRT vs DCA) 0.82 0.51 0.67 0.84 0.74
p value (VMAT vs DCA) 0.56 0.39 0.78 0.65 0.43
GTV Dmin GTV D95 GTV D50 GTV D5 GTV Dmax
IMRT 1.6% (−0.5 to 10.3%) 1.2% (−0.3 to 6.4%) 0.1% (−1.3 to 3.2%) −1.2% (−3.5 to 0.8%) −1.8% (−4.7 to 0.8%)
VMAT 1.9% (−0.3 to 8.9%) 0.9% (−0.5 to 6.7%) 0.3% (−1.8 to 3.5%) −0.9% (−3.2 to 0.8%) −1.6% (−3.9 to 0.9%)
DCA 1.2% (−0.5 to 6.8%) 1.0% (−0.4 to 5.6%) 0.5% (−1.0 to 3.3%) −0.5% (−2.5 to 0.8%) −1.0% (−3.1 to 1.0%)
p value (IMRT vs DCA) 0.78 0.81 0.88 0.59 0.62
p value (VMAT vs DCA) 0.29 0.87 0.67 0.75 0.71