Skip to main content
. 2018 Jan 30;7(3):e007736. doi: 10.1161/JAHA.117.007736

Table 2.

Comparison of Diagnostic Performance for Predicting Hemodynamically Significant Stenosis in Single‐Vessel Versus Multivessel Disease

Measure Per‐Patient Level Per‐Vessel Level
Single‐Vessel (n=25) Multivessel (n=67) Single‐Vessel (n=75) Multivessel (n=201)
Perfusion CMR (95% CI) Perfusion CMR (95% CI) Combined Perfusion CMR/CS Blood Flow (95% CI) Perfusion CMR (95% CI) Perfusion CMR (95% CI) Combined Perfusion CMR/CS Blood Flow (95% CI)
Functional CAD, % 48.0 77.6 77.6 16.0 47.3 47.3
Sensitivity, % 83 (52–98)
10/12
79 (65–89)
41/52
92 (82–98)
48/52
83 (52–98)
10/12
64 (54–74)
61/95
86 (78–93)
82/95
Specificity, % 85 (55–98)
11/13
73 (45–92)
11/15
73 (45–92)
11/15
95 (87–99)
60/63
81 (72–88)
85/106
73 (63–81)
77/106
NPV, % 85 (55–98)
11/13
50 (28–72)
11/22
73 (44–93)
11/15
97 (89–100)
60/62
72 (63–80)
85/119
86 (77–92)
77/90
PPV, % 83 (52–98)
10/12
91 (79–98)
41/45
92 (82–98)
48/52
77 (46–95)
10/13
75 (65–84)
61/82
74 (65–82)
82/111
LR (+) 5.42 2.96 3.46 17.5 3.4 3.15
LR (−) 0.20 0.29 0.10 0.18 0.44 0.19
AUC 0.93 (0.76–0.99) 0.76 (0.64–0.86) 0.88 (0.80–0.97) 0.95 (0.87–0.99) 0.80 (0.73–0.85) 0.84 (0.70–0.90)

Values for sensitivity, specificity, PPV, NPV, and AUC are presented with 95% CI. AUC indicates area under the receiver operator characteristic curve; CAD, coronary artery disease; CI, confidence interval; CMR, cardiovascular magnetic resonance; CS, coronary sinus; LR, likelihood ratio; NPV, negative predictive value; PPV, positive predictive value.