Skip to main content
. 2018 Feb 28;2018:9189354. doi: 10.1155/2018/9189354

Table 3.

Failure mode counts of all the specimens after microtensile test.

Resin cement Polishing method 24-hour water storage 2-year water storage
(a) (b) (c) (a) (b) (c)
Etch-and-rinse A 17 0 3 15 3 2
B 19 0 1 16 2 2
Self-etch A 18 1 1 18 1 1
B 18 0 2 17 2 1
Self-adhesive A 20 0 0 19 0 1
B 18 0 2 18 0 2

Failure modes: (a) adhesive failure (failure within dentin/resin cements interface); (b) cohesive failure (failure solely within resin cements); (c) mixed failure (partially cohesive failure within resin cements with some adhesive failure).