Skip to main content
. 2018 Jan 29;7(2):13. doi: 10.3390/jcm7020013

Figure 2.

Figure 2

US-guided plasma rich in growth factors injection for the radial nerve. The procedure was performed in sterile conditions in an outpatient setting. The multi-frequency linear probe was aligned with the long axis of the radial nerve, and a 22-gauge needle (25 mm) was inserted into the radial nerve. The accuracy of platelet-rich plasma (PRP) infiltration was confirmed by direct visualization by US imaging.